Model: ELP-515

Features:
- Advanced double-piston pump and electronic residual technique, greatly improves the flow rate precision and repeatability of the pump.
- Analytical task can be completed in single sampling, with automatic processing of chromatograph data and obtaining perfect spectra.
- Backstage operation function enables data processing to the existing spectra, while analysis is going on.
- Complete PC control function, realizing parameter control and real-time monitoring to all parts, including column oven.
- High pressure solvent delivery pump adopting electronic pulsation suppression technology displacing traditional mechanical buffer to thoroughly solve the problem caused by frequent leakage of mechanical buffer, and to reduce the dead volume of solvent delivery system to the minimum.
- Interface language can be switched between Chinese and English, with simple operation.
- The gradient program of the pump and wavelength time-program of the detector can be established.
- The test report format can be flexibly modified.
- The wavelength positioning of Multi-wavelength UV-Vis detector is realized via the grating's turning which is directly controled by the SCM( Single Chip Micyoco). It has taken place the conventional sine-pole mechanics (monochromator), eliminating the error of wavelength positioning brought by the mechanical abrasion and returning error of the Guide-screw transmission, and also avoiding the monochromator's hitting accident which might be brought by false operation.
- Timer turn-off function is provided.
Specifications:
Spectral Bandwidth:
0.2nm
0.4nm
0.8nm
1.6nm
Main Specification:
Baseline stability:
0.005A/30min
Resolution:
Better than 0.3nm.
Flow rate range::
0.001~9.99mL/min in 0.001mL/min increments
Structure::
double-piston pump
Flow rate precision:
<0.5%
Repeatability:
<0.1%
Pulsation::
<0.04MPa
Pressure range:
0~40MPa
Gradient mode:
a low pressure gradient system up to 4 solvents and a high pressure gradient system up to 2 solvents
Remote control:
RS-232 connector, PC control
System protection:
Soft start, P min and P max adjustment
Display:
LCD, 2×16
Dimensions:
350×190×210mm
Baseline drift:
15×10-5AU/h at 240nm, t=1.0s
Baseline noise::
2×10-5AU at 240nm, t=1.0s
Wave length accuracy:
±0.5nm
Time constants::
0.1/0.2/0.5/1.0/2.0/5.0/10.0
Analog output::
±1V
Auto-zero range::
full scale
Highest temperature establishing, overrun temperature alarming. Control mode::
PID
Temperature control range::
ambient~100℃
Temperature accuracy::
±0.3℃
Safety setting-up::
overrun temperature limit alarming
Light Source System:
Lamp current :
0~15mA
Lamp turret:
Automatic 8×2 lamp turrets (Two high performance hollow cathode lamps can be mounted on each turret
Lamp power supply mode:
200Hz narrow square wave pulse