Model: EAA-515

Features:

  • A flame emission burner head can be installed to perform flame emission analysis to akali metais as K, Na etc.
  • Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is (2)
  • Adopting large-scale programmable logic array and Inter I2C bus technology (3)
  • Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system (3)
  • Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling wate supply and over-heating in graphite furnace system (2)
  • asy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization
  • Auotmatic calculation of sample concentration (content), mean value, standard deviation and relative standard deviation calculation
  • Automatic 6-lamp turret, automatic adjustment of lamp current and optimization of light beam position
  • Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters, automatic ignition and automatic gas flow setting
  • Automatic sample dilution, automatic curve fitting, automatic sensitivity correction (2)
  • Automatic spectral bandwidth changing (4)
  • Automatic wavelength scanning and peak picking (4)
  • Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor (2)
  • European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system (2)
  • Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact (2)
  • Measured data and final results can be printed out and edited in Excel format
  • Multi-function autosampler features automatic standard sample preparation, automatic correction of sampling probe depth, automatic tracing and correction of liquid surface height in the sample vessel, with the sampling accuracy of 1% and reproducibility of 0.3%, realizing fully automation of graphite furnace analysis
  • Mutil-elements determination in sequence to the same sample
  • The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temeperature is continuously adju (3)

Specifications:

Background correction:
The D2 lamp background correction capability at 1A is better than 30 times
The S-H background correction capability at 1.8A is better than 30 times.
Lamp turret:
Motorized 6-lamp turret ( Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.);
Lamp current adjustment:
Wide pulse current: 0~25mA
Narrow pulse current: 0~10mA
Lamp power supply mode:
400Hz square wave pulse; 100Hz narrow square wave pulse+400Hz wide square wave pulse
Air-C2H2 flame Oxygen-rich Air-C2H2 flame:
Cu: Characteristic concentration≤0.025mg/L
Detection limit≤0.006mg/L;Ba: Characteristic concentration ≤ 0.22mg/L
Al: Characteristic concentration ≤ 0.4mg/L
Function Expansion:
Hydride vapor generator can be connected for hydride analysis

Main Specification:

Wave length range:
190-900nm
Wave length accuracy:
Better than ±0.25nm
Resolution:
Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2n
Baseline stability:
0.004A/30min

Optical System:

Monochromator:
Single beam, Czerny-Turner design grating monochromator
Grating:
1800 l/mm
Focal length:
277mm
Spectral Bandwidth:
0.1nm, 0.2nm, 0.4nm, 1.2nm, auto-switch over

Flame Atomizer:

Burner:
10cm single slot all-titanium burner
Spray chamber:
Corrosion resistant all-plastic spray chamber
Nebulizer:
High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min

Graphite Furnace:

Temperature range:
Room temperature~3000ºC
Heating rate:
2000℃/s
Graphite tube dimensions:
28mm(L)×8mm(OD)
Characteristic mass:
Cd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g
Precision:
Cd≤3%, Cu≤3%, Mo≤4%

Detection and Data Processing System:

Detector:
R928 Photomultiplier with high sensitivity and wide spectral range.
Software:
Under Windows operating system
Analytical method:
Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic ca
Repeat times:
1-99 times, automatic calculation of mean value, standard deviation and relative standard deviation.
Multi-task Functions:
Sequential measurement for multi-element determination to the same sample
Condition reading:
With model function
Result printing:
Measurement data and final analytical report printout, editing with Excel
Communication:
Standard RS-232 serial port

Dimensions and weight:

Main unit:
107×49×58cm, 140kg
Graphite furnace:
42×42×46cm, 65kg
Autosampler:
40×29×29cm, 15kg

Graphite Furnace Autosample:

Sample tray capacity:
55 sample vessels and 5 reagent vessels
Vessel materia:
Polypropylene
Vessel volume:
3ml for sample vessel, 20ml for reagent vessel
Minimum sampling volume:
1μl
Repeatable sampling times:
1 -99 times
Sampling system:
Accurate dual pump system, with 100μl and 1ml injiectors