Benchtop Ion Meter 25-BIM111 Catalog

Download

Overview :

Lab Expo Benchtop Ion Meter 25-BIM111 delivers precise lead ion testing across diverse water sources. It supports 2 to 5-point calibration for improved testing accuracy and reliability. Built-in Pb range of 0.2 to 20700 ppm ensures wide coverage for lead ion testing. Equipped with a large LCD, offering clear visibility for convenient data reading. Our Benchtop Ion Meter is widely used for lead ion testing across a variety of water types, including drinking water, distilled water, and wastewater.

Specifications:
Ion Measurement Range Pb Range: 1×108 – 0.1M, 0.2-20700 ppm
Ion Measurement Accuracy ± 1 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration Points 2 to 5 Points
Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
mV Range (-1999.9) to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1 mV
Temperature Measurement Range 0 to 105 °C, 32 to 221 °F
Temperature Accuracy ± 0.5 °C, ± 0.9 °F
Temperature Resolution 0.1°C
Temperature Compensation 0 to 100 °C, 32 to 212 °F
Compensation Mode Manual or Automatic
Data Hold Function Manual or Automatic Endpoint Detection
Reset Function Yes
Stability Condition Low or High
Calibration Due 0 to 31 Days
Power Off Manual or Automatic (10,20,30 Minutes)
Memory Stores up to 500 Sets of Data
Output USB communication interface
Connector BNC
Display LCD (130 × 110 mm)
Power Supply DC 5 V, Using AC Adapter, AC 220 V / 50 Hz
Dimension 210 × 188 × 60 mm
Weight 1.5 Kg

Features:

  • Stability indicator with low or high condition detection
  • USB communication interface for data transfer
  • Reset function enables system reboot capability
  • Electrode diagnosis monitors sensor performance status
  • Calibration reminder tracks 0 to 31 day intervals
  • Auto-hold function captures endpoint detection automatically

Applications:

FunctionImplementationWater quality testing labs0.2 to 20700 ppm Pb range supports lead ion analysis across samplesDrinking water facilities±1% F.S. ion measurement accuracy ensures reliable compliance screeningWastewater treatment plantsUSB communication interface enables data transfer for record keepingClinical laboratoriesLCD (130 × 110 mm) display allows clear visibility during sample analysisIndustrial process controlStores up to 500 sets of data for long-term monitoring and trend evaluation

Standard Accessories:

Pb ion selective electrode

Temperature probe

Standard solution (1000 ppm)

Ionic strength adjuster (30 ml)

www.labexpo.com