Gas Chromatography 30-GCG100 Catalog

Download

Overview :

Gas chromatography system comes with different detectors and each detector individually controls the temperature of the system. This gas chromatography comes with packed column injectors, split/split less injectors, capillary and cool-on column. It is possible to achieve lower limit of detection using these unique injector system. It gives accurate, high precision control, reliable results.

Specifications:
Chromatography column type Capillary and Packed column
Chromatography column length 100 to 500 mm
Chromatography column diameter 0.2 to 0.5 mm
Temperature operating range Higher than the room temperature of 5 ℃ to 450 ℃
Maximum programmed heating speed 120 ℃/min
Programmed temperature steps 7 steps
Temperature setting precision 1 °C
Programmed heating rate 0.1 to 120 °C/min (increment of 0.1 °C)
Furnace dimension 280 × 300 ×180 mm
Injectors Packed column injectors, split/splitless capillary column injectors, and cool on-column injectors.
Detectors Following detectors can be selected as per the requirement
FID Maximum temperature control: 400 °C LOD: ≤ 5 × 1012 g / s [n - C16] Linear dynamic range: ≥ 107 Drift: ≤ 5 × 10-13 A / 30 min Noise: ≤ 2 × 10-13 A
TCD Maximum temperature control: 400 °CLOD: ≥ 10000 mv.ml / mg [n - C16]Linear dynamic range: ≥ 104 Drift: ≤ 10 µV / 30 minNoise: ≤ 20 µA
FPD Maximum temperature control: 250 °CLOD: ≤2×10-13 g / s (P), ≤ 5 × 10-11 g / s (S)Linear dynamic range: ≥ 103 (P), ≥ 102 (S)Drift: ≤ 4 × 10-11 A / 30 minNoise: ≤ 2 × 10-12 A
ECD Maximum temperature control: 350 °CLOD: ≤ 1 × 10-14 g / ml (y - 666)Linear dynamic range: ≥ 104 Drift: ≤ 5 µV / 30 minNoise: ≤ 20 µA
NPD Maximum temperature control: 400 °CLOD: ≤ 5 × 10-13 g / s (P), ≤ 1 × 1012 g / s (N)Linear dynamic range: ≥ 103 (P), ≥ 103 (N)Drift: ≤ 2.5 × 10-12A / 30 minNoise: ≤ 4 × 10-13 A
PDHID LOD: ≤ 5 ppb

Features:

  • Capillary and packed column compatibility with split/splitless and cool on-column injectors
  • Operating temperature above RT up to 450 C with heating rate 0.1 to 120 C/min
  • 7-step temperature programming with 1 C setting precision
  • Selectable detectors including FID, TCD, FPD, ECD, NPD and PDHID
  • Individual detector temperature control with LCD display and self-diagnosis

Applications:

FunctionImplementationPetrochemical analysisMulti-detector configuration supports hydrocarbon profilingGas industry testingPacked and capillary columns enable diverse gas separationPharmaceutical quality controlPrecise temperature programming ensures reproducible resultsFood and chemical analysisLow detection limits support trace compound identificationOil refining evaluationHigh heating rate manages complex mixture resolution

www.labexpo.com