Request Quote
Scan the QR code below to connect with us on WhatsApp.
Request Quote
Scan the QR code below to connect with us on WhatsApp.
High Performance Liquid Chromatograph LE-HPLC101 operates at a flow rate of 0.001 to 10.000 mL/min. It offers a wavelength range of 190 to 900 nm for broad-spectrum detection. Equipped with deuterium and tungsten lamp to provide accurate and sensitive analysis. Built-in injection system ensures precise, repeatable sample delivery with multiple injection modes. Our HPLC enables stage-wise temperature control with interval heating and cooling.
| Pump Type | Four Element Infusion Pump with Double Plunger Reciprocating System |
| Flow Rate | 0.001 to 10.000 mL/min (increment 0.001 mL/min) |
| Flow Accuracy | ±0.5% (at 1 mL/min, water) |
| Flow Precision | ≤0.06% RSD |
| Pressure Range | 0 to 10500 psi (72 MPa) |
| Gradient Accuracy | ±0.5% |
| Gradient Repeatability | ≤0.2% SD |
| Pressure Pulsation | ≤1% (at 1 mL/min, water, >10 MPa) |
| UV Detector Light Source | Deuterium Lamp, Tungsten Lamp |
| Wavelength Range | 190 to 900 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Precision | ±0.1 nm |
| Noise | ±5.0×10⁻⁶ AU (JJG) / ±3.5×10⁻⁶ AU (ASTM) |
| Baseline Drift | 1×10⁻⁴ AU/hr |
| Linear Range | >5×10⁴ (JJG) / >2.5 AU (ASTM) |
| Spectral Bandwidth | 8 nm |
| Fluorescence Light Source | 150 W Xenon Lamp |
| Wavelength Range | 200–650 nm (up to 900 nm optional) |
| Detector | PMT |
| Raman SNR | >1200 |
| ELSD Light Source | 650 nm Semiconductor Laser |
| Evaporation Temperature | Ambient to 130°C |
| Atomization Temperature | Ambient to 56°C |
| Min Detection Concentration | <1 ng |
| Dynamic Range | 10⁴ |
| Refractive Index Range | 1.00 to 1.75 |
| Detection Range | 0.25 to 512 μRIU |
| Noise | ≤5 nRIU |
| Temperature Control | Off, 30 to 50°C |
| Column Oven Capacity | Holds ≥4 columns (300 mm) |
| Temperature Control Range | Ambient +5°C to 85°C |
| Temperature Accuracy | ±1.0°C |
| Temperature Stability | ±0.1°C |
| Injection Modes | Full loop, Partial loop, μL pickup |
| Sample Positions | ≥108 (1.5 mL vials) |
| Sample Accuracy | ≤0.3% RSD |
| Sample Residue | <0.0025% |
| Compliance | FDA 21 CFR Part 11 / GMP / GLP |
| Environmental Temperature | 15 to 35°C |
| Environmental Humidity | <85% |
| Power Supply | Single phase 220V ±10% 50/60Hz |
FunctionImplementationPharmaceutical analysisHigh pressure gradient control enables compound separationFood and environmental testingBroad wavelength detection supports multi-component screeningTrace compound quantificationLow noise UV detection enhances sensitivityComplex mixture profilingMulti-detector compatibility expands analytical capabilityRegulatory compliance testingSupports FDA 21 CFR Part 11, GMP and GLP workflows
Software
In-line Mobile phase Degasser
C18-2Pcs
Amino column 1pc
Solvent filter 1pc
Filter head 1pc
Filter membrane 1pc