Lab Expo Multi-Parameter Water Quality Analyzer 25-MWA100 with portable suitcase design, directly measures turbidity, chemical oxygen demand, ammonia and total phosphorous content of water sample, without any power supply. Incorporated with a 15 samples intelligent reactor, it meets the demand of user for testing large quantities of water samples. Its rated power of reactor is adjusted, according to the quantity of load.
| COD Determination Range | 2 to 10,000 mg/L |
| COD Measurement Accuracy | COD < 50 mg/L: ≤ ± 10%, COD > 50 mg/L: ≤ ± 5% |
| COD Minimum Detection Limit | 0.1 mg/L |
| COD Measurement Time | 20 minutes |
| COD Repeatability | ≤ ± 5% |
| COD Consumables | Colorimetric Tubes and Cuvette |
| COD Reactor Digestion Temperature | 165 ± 0.5°C |
| COD Reactor Digestion Time | 10 minutes |
| COD Reactor Time Setting Switches | 3 pcs |
| COD Anti-Chlorine Interference | (Cl) < 1000 mg/L: No effect |
| Ammonia Nitrogen Determination Range | 0.02 to 60 mg/L |
| Ammonia Nitrogen Measurement Accuracy | ≤ ± 10% |
| Ammonia Nitrogen Minimum Detection Limit | 0.01 mg/L |
| Ammonia Nitrogen Measurement Time | 10 to 15 minutes |
| Ammonia Nitrogen Repeatability | ≤ ± 5% |
| Ammonia Nitrogen Consumables | Colorimetric Tubes and Cuvette |
| Ammonia Nitrogen Reactor Time Setting Switches | 3 pcs |
| Total Phosphorous Determination Range | 0.002 to 20 mg/L |
| Total Phosphorous Measurement Accuracy | ≤ ± 5% |
| Total Phosphorous Minimum Detection Limit | 0.001 mg/L |
| Total Phosphorous Measurement Time | 35 to 50 minutes |
| Total Phosphorous Repeatability | ≤ ± 5% |
| Total Phosphorous Consumables | Colorimetric Tubes and Cuvette |
| Total Phosphorous Reactor Digestion Temperature | 120 ± 0.5°C |
| Total Phosphorous Reactor Digestion Time | 30 minutes |
| Total Phosphorous Reactor Time Setting Switches | 3 pcs |
| Turbidity Determination Range | 0.5 to 400 NTU |
| Turbidity Measurement Accuracy | ≤ ± 5% |
| Turbidity Minimum Detection Limit | 0.1 NTU |
| Turbidity Measurement Time | 1 minute |
| Turbidity Repeatability | ≤ ± 5% |
| Turbidity Consumables | Colorimetric Cuvette |
| Light Source Life | 100,000 hours |
| Optical Stability | ≤ 0.001 A/10 min |
| Number of Curves | 166 |
| Storage Data | 12,000 |
| Display | LCD (320 × 240) |
| Interface | USB |
| Power Supply | AC 200 V |
| Dimension | 550 × 300 × 250 mm |
| Gross Weight | 21 kg |
FunctionImplementationField water testing sitesPortable suitcase design enables on-site analysis without external power supplyHigh-volume sample processing15 samples intelligent reactor supports batch testing of numerous water specimensEnvironmental monitoring programsTurbidity range 0.5 to 400 NTU detects particulate levels in natural watersIndustrial effluent verificationCOD determination range 2 to 10,000 mg/L quantifies organic pollution in wastewaterLaboratory quality control labsStorage capacity of 12,000 data points retains extensive historical test records
| Accessories no. | Name |
| 1 | Protective cover |
| 2 | Cooling rack |
| 3 | Cuvette rack |
| 4 | Tube rack |
| 5 | Reagent proportional |
| 6 | Printing paper |