Lab Expo Multi-Parameter Water Quality Analyzer 25-MWA101 is a high quality analyzer with benchtop design, simultaneously measures turbidity, chemical oxygen demand, ammonia and total phosphorous content of water sample. The aviation insulation protective layer present above digestion hole, effectively prevents scalds. The imported heat resistant protective cover ensures the safety and reliability of the experiment.
| COD Determination Range | 5 to 5000 mg/L |
| COD Measurement Accuracy | COD < 50 mg/L: ≤ ± 10%, COD > 50 mg/L: ≤ ± 5% |
| COD Minimum Detection Limit | 0.1 mg/L |
| COD Measurement Time | 20 minutes |
| COD Repeatability | ≤ ± 5% |
| COD Processing Sample Number per Batch | 12 pcs |
| COD Consumables | Colorimetric Tubes and Cuvette |
| COD Reactor Digestion Temperature | 165 ± 0.5°C |
| COD Reactor Digestion Time | 10 minutes |
| COD Reactor Time Setting Switches | 3 pcs |
| COD Anti-Chlorine Interference | (Cl) < 1000 mg/L: No effect |
| Ammonia Nitrogen Determination Range | 0.02 to 30 mg/L |
| Ammonia Nitrogen Measurement Accuracy | ≤ ± 10% |
| Ammonia Nitrogen Minimum Detection Limit | 0.01 mg/L |
| Ammonia Nitrogen Measurement Time | 10 to 15 minutes |
| Ammonia Nitrogen Repeatability | ≤ ± 5% |
| Ammonia Nitrogen Processing Sample Number | 20 pcs |
| Ammonia Nitrogen Consumables | Colorimetric Tubes and Cuvette |
| Ammonia Nitrogen Reactor Time Setting Switches | 3 pcs |
| Total Phosphorous Determination Range | 0.002 to 10 mg/L |
| Total Phosphorous Measurement Accuracy | ≤ ± 5% |
| Total Phosphorous Minimum Detection Limit | 0.001 mg/L |
| Total Phosphorous Measurement Time | 35 to 50 minutes |
| Total Phosphorous Repeatability | ≤ ± 5% |
| Total Phosphorous Processing Sample Number | 12 pcs |
| Total Phosphorous Consumables | Colorimetric Tubes and Cuvette |
| Total Phosphorous Reactor Digestion Temperature | 120 ± 0.5°C |
| Total Phosphorous Reactor Digestion Time | 30 minutes |
| Total Phosphorous Reactor Time Setting Switches | 3 pcs |
| Turbidity Determination Range | 0.5 to 400 NTU |
| Turbidity Measurement Accuracy | ≤ ± 5% |
| Turbidity Minimum Detection Limit | 0.1 NTU |
| Turbidity Measurement Time | 1 minute |
| Turbidity Repeatability | ≤ ± 5% |
| Turbidity Consumables | Colorimetric Cuvette |
| Light Source Life | 100,000 hours |
| Optical Stability | ≤ 0.001 A/10 min |
| Number of Curves | 56 |
| Storage Data | 12,000 |
| Display | LCD (320 × 240) |
| Interface | USB |
| Power Supply | AC 200 V |
| Dimension | 450 × 300 × 250 mm |
| Weight | 18 kg |
FunctionImplementationWater treatment plantsCOD determination range 5 to 5000 mg/L supports broad contaminant analysisEnvironmental monitoring labsTurbidity measurement time 1 minute enables rapid field screeningIndustrial effluent testingAmmonia nitrogen processing sample number 20 pcs allows batch verificationResearch institutionsStorage data 12,000 retains extensive historical datasetsQuality control facilitiesOptical stability ≤ 0.001 A/10 min ensures consistent calibration performance
| Accessories no. | Name |
| 1 | Protective cover |
| 2 | Cooling rack |
| 3 | Cuvette rack |
| 4 | Tube rack |
| 5 | Reagent proportional |
| 6 | Printing paper |