Multi-Parameter Water Quality Analyzer 25-MWA101 Catalog

Download

Overview :

Lab Expo Multi-Parameter Water Quality Analyzer 25-MWA101 is a high quality analyzer with benchtop design, simultaneously measures turbidity, chemical oxygen demand, ammonia and total phosphorous content of water sample. The aviation insulation protective layer present above digestion hole, effectively prevents scalds. The imported heat resistant protective cover ensures the safety and reliability of the experiment.

Specifications:
COD Determination Range 5 to 5000 mg/L
COD Measurement Accuracy COD < 50 mg/L: ≤ ± 10%, COD > 50 mg/L: ≤ ± 5%
COD Minimum Detection Limit 0.1 mg/L
COD Measurement Time 20 minutes
COD Repeatability ≤ ± 5%
COD Processing Sample Number per Batch 12 pcs
COD Consumables Colorimetric Tubes and Cuvette
COD Reactor Digestion Temperature 165 ± 0.5°C
COD Reactor Digestion Time 10 minutes
COD Reactor Time Setting Switches 3 pcs
COD Anti-Chlorine Interference (Cl) < 1000 mg/L: No effect
Ammonia Nitrogen Determination Range 0.02 to 30 mg/L
Ammonia Nitrogen Measurement Accuracy ≤ ± 10%
Ammonia Nitrogen Minimum Detection Limit 0.01 mg/L
Ammonia Nitrogen Measurement Time 10 to 15 minutes
Ammonia Nitrogen Repeatability ≤ ± 5%
Ammonia Nitrogen Processing Sample Number 20 pcs
Ammonia Nitrogen Consumables Colorimetric Tubes and Cuvette
Ammonia Nitrogen Reactor Time Setting Switches 3 pcs
Total Phosphorous Determination Range 0.002 to 10 mg/L
Total Phosphorous Measurement Accuracy ≤ ± 5%
Total Phosphorous Minimum Detection Limit 0.001 mg/L
Total Phosphorous Measurement Time 35 to 50 minutes
Total Phosphorous Repeatability ≤ ± 5%
Total Phosphorous Processing Sample Number 12 pcs
Total Phosphorous Consumables Colorimetric Tubes and Cuvette
Total Phosphorous Reactor Digestion Temperature 120 ± 0.5°C
Total Phosphorous Reactor Digestion Time 30 minutes
Total Phosphorous Reactor Time Setting Switches 3 pcs
Turbidity Determination Range 0.5 to 400 NTU
Turbidity Measurement Accuracy ≤ ± 5%
Turbidity Minimum Detection Limit 0.1 NTU
Turbidity Measurement Time 1 minute
Turbidity Repeatability ≤ ± 5%
Turbidity Consumables Colorimetric Cuvette
Light Source Life 100,000 hours
Optical Stability ≤ 0.001 A/10 min
Number of Curves 56
Storage Data 12,000
Display LCD (320 × 240)
Interface USB
Power Supply AC 200 V
Dimension 450 × 300 × 250 mm
Weight 18 kg

Features:

  • Colorimetric digestive system with timing functions
  • Intelligent data analysis USB infrared communication
  • Built-in mini printer for immediate output
  • High accuracy measurement readings ≤ ±10%
  • User-friendly operation interface controls

Applications:

FunctionImplementationWater treatment plantsCOD determination range 5 to 5000 mg/L supports broad contaminant analysisEnvironmental monitoring labsTurbidity measurement time 1 minute enables rapid field screeningIndustrial effluent testingAmmonia nitrogen processing sample number 20 pcs allows batch verificationResearch institutionsStorage data 12,000 retains extensive historical datasetsQuality control facilitiesOptical stability ≤ 0.001 A/10 min ensures consistent calibration performance

Standard Accessories:
Accessories no.Name
1Protective cover
2Cooling rack
3Cuvette rack
4Tube rack
5Reagent proportional
6Printing paper