Real-Time PCR 62-RTP201 Catalog

Download

Overview :

Lab Expo Real-Time PCR 62-RTP201 comes with 96 well capacity PCR machine with, 1 to 36°C gradient temperature range, and fast speed dual colour scanning mode. Its wide fluorescence wavelength range with innovative 4 channel design, optimizes thermal performance and maximizes convenience during operation. With its unique block dissipation technology, it provides precise temperature control and thermal gradient which easily optimizes PCR assays.

Specifications:
Sample Capacity 96-Well PCR plate12 × 8-strip 96 × 0.2 ml(Bottom Transparent)
Emission Wavelength 500 to 800 nm
Excitation Wavelength 300 to 800 nm
Sample Volume Range 5 to 100μl
Program Max 20 Segments for Each Program, Max 99 Cycles
Dynamics Range 10 to 1010 Copies
Max. channels number of fluorescence detection 4 channels
Detected Fluorescence F1 : FAM, SYBR Green 1; F2 : VIC, HEX, TET, JOE; F3 : CY3, NED, TAMRA; F4 : ROX,TEXAS-RED
Block Temp. Range 4 to 105℃ (Minimum Increment: 0.1℃), SOAK Low Temp. Conservation Function
Temp. Control Accuracy ≤ ± 0.1 ℃
Temp. Fluctuation ≤ ± 0.1 ℃
Temp. Uniformity ≤ ± 0.3 ℃
Ramping Rate 4.0 ℃/sec
Temp. Control Mode BLOCK/Tube Simulation Mode (Automatic Control based On Sample Volume )
Gradient Temp. Range 1 to 36 ℃
Hot-lid Temp. Range 30 to 110℃ (Adjustable, default 105℃, Automatic Hot-lid )
Fluorescence DetectionRepeatability 0.05
Operation Mode Continuous
Scan Mode Entire Plate or Designated Line
Scan Period 5.5 sec
Operation System Microsoft: Windows2000/XP/vista/Windows7Software: Excel2003/2007 Access: 2003/2007
PC Configuration Memory : 512 M; Hard Disk : 10 GB; CPU : Pentium® 4; Virtual Memory : ≥ 1000 MB
Power Supply 100 to 240 V, 50/60 Hz, 600 W
Dimension ( L × W × H ) 430 x 395 x 352 mm
Socket RS 232C Adapter

Features:

  • Ferrotec Peltier cooler with 600W power supply
  • Four individual filters for fluorescence detection wavelength range
  • USB and Bluetooth data transfer capability
  • High long life LED illumination system
  • Dual high sensitivity PMT synchronous detection capability
  • Panoramic view of experimental results display

Applications:

FunctionImplementationClinical diagnostics labs96-Well PCR plate capacity supports high-throughput sample processingResearch laboratories1 to 36℃ gradient temperature range optimizes assay developmentQuality control facilities≤ ± 0.1℃ temp. control accuracy ensures reproducible resultsIndustrial testing environments5 to 100μl sample volume range accommodates varied reagent volumesPharmaceutical R&D unitsMax 99 cycles enables extended amplification protocols