Table top spectrophotometer is a high performance spectrophotometer with test caliber (top port) upward. The solid samples (paper sheets, cloth) can be placed directly on the measurement port & particles like pellets, tablets, powder (dye, food powder, chemical powder), paste (thick paste, opaque samples can be placed in a round shape plates & then in the mouth of the measurement unit. It is adopted with every test calibration ETC technology, where the standard white boards is included in the optical system for reliable, accuracy of every measurement.
Illumination system | d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Sensor | Dual light path sensor array |
Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
Wavelength range | 400-700 nm |
Wavelength interval | 10 nm |
Half spectral width | 5 nm |
Reflectivity range & resolution | 0 to 200%, 0.01% |
Observation Angle | 2°/10° |
Measurement time interval | 0.5 s |
Measurement time | 2 s |
Measuring aperture | 25.5*10 mm (cuvette support) |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell Mi, CMYK |
Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 color classification |
Other colorimetric indices |
WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger,Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, staining fastness, color fastness, APHA, Astm color, ISO illuminance, saybolt |
Repeatability |
Transmittance: standard deviation within 0.08% color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03 |
Work temperature range | 0-45°C, relative humidity 80% or below (at 35°C), no condensation |
Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
Data being displayed | Sample\'s color values,color difference values/graph,pass/fail results,color error tendency,color value simulation, color difference values, display measurement area,history data color simulation,manual input standard sample, generate measurement report |
Interface | USB |
Data storage | Mass storage (on PC) |
Light source longevity | 5 years, 1.5 million tests |
Dimension (L*W*H) | 475 × 340 × 150 mm |
Weight | 7 kg |
Accessories No. | Name |
1 | Power cord |
2 | USB cable |
3 | Driving software |
4 | Color QC software |
5 | Black and white calibration tile |
Transmittance spectrophotometer is used in the measurement of range of liquids and solvents like resins, solvents, oils etc. to be used in food, chemical, textile, life science industries.
Lab Expo Inc.
Lab Expo Inc, 200 Continental Drive Newark, Delaware 19713 USA
Email: info@labexpo.com | Website: www.labexpo.com |