Chemilluminescence Imaging System 36-CIS101

Lab Expo Chemiluminescence Imaging System 36-CIS101 is based on chemiluminescence, offers exceptionally high sensitivity and dynamic range. This system is able to detect far weaker signals, offers higher sensitivity and wider linear range. It has 16-bit cooled CCD camera which reduces the background noise during long exposure time. This system offers precise automatic exposure, facilities to crop, rotate and counter colour process for the images obtained.

$26,712.00 $ 22260

Chemilluminescence Imaging System 36-CIS101 - Specifications

Display 10 inch digital display screen
Storage 64 GB SSD
CCD size 12.49 mm × 9.99 mm
Pixels 2750 × 2200, 4.54 × 4.54 um
A/D 16 bit
Quantum efficiency > 78 %
Grayscale 65536
lens F0.95 motorized lens
Epi-LED white Yes
Light source Blue LED light transmission
Cooling temperature 65 ºC below ambient
Filter wheel Motorized wheel with 5 sockets
Filter 590 nm
Software Image acquision and analysis software
Net Weight 18.3 kg
Gross Weight 25 kg

Chemilluminescence Imaging System 36-CIS101 - Key Features

  • 10 inch digital display screen with real-time visualization
  • Motorized lens system F0.95 aperture for low-light capture
  • Cooling temperature 65C below ambient reducing thermal noise
  • Filter wheel motorized with five position socket configuration
  • Grayscale depth 65536 levels for enhanced contrast differentiation

Chemilluminescence Imaging System 36-CIS101 - Applications

FunctionImplementation
Clinical detection labs65 ºC cooling sustains low-noise signal capture
Research imaging workflows2750 × 2200 pixels enables high-resolution documentation
Quality control assays16-bit A/D supports precise quantitative analysis
Industrial testing facilitiesF0.95 motorized lens optimizes light throughput
Pharmaceutical screening units>78% quantum efficiency detects weak chemiluminescent signals

Chemilluminescence Imaging System 36-CIS101 - Optional Accessories

White LED light as source of transmission
Filters with range of 460 nm, 530 nm, 630 nm, 670 nm
Fluorescent LED light: 470 nm,530 nm, 620 nm

Chemilluminescence Imaging System 36-CIS101 - Catalog

Related Chemiluminescence Imaging System

Lab Expo Chemiluminescence Imaging System units are used for detection and documentation of chemiluminescent signals in biomolecular analysis workflows. The range includes CCD-based imaging systems with high-resolution sensors (2750 × 2200 pixels), 16-bit signal conversion, and controlled image acquisition. Systems integrate optical assemblies, temperature control, and data storage, suitable for protein analysis, gel documentation, and laboratory imaging applications.