Biological Safety Cabinet 99-BSC101

Biological Safety Cabinet 99-BSC101 has a down-flow velocity of 0.35 m/s and an inflow velocity of 0.55 m/s to keep samples and operators safe from contamination. It filters over 99.9995% of airborne contaminants at 0.12μm ensuring a clean and safe working space. It features a high-quality ULPA filter that effectively captures airborne particles providing reliable protection. Our Biosafety Cabinet has an integrated touchscreen display for easy monitoring and control.

$8,275.00 $ 6896

Specifications

Filtration Efficiency >99.9995% at 0.12μm
Down Flow Velocity 0.35 m/s
Inflow Velocity 0.55 m/s
Air Supply and Exhaust Filters ULPA filters
Air Cleanliness ISO 4 Class
Execution Standards YY0569 (GB 4793.1, GB/T 18268.1)
Personnel Protection A. Total colony in impaction sampler <10 CFU/time B. Total colony in slot sampler <5 CFU/time
Product Protection Total colony in culture dish <5 CFU/time
Cross-Contamination Protection Total colony in culture dish <2 CFU/time
Light Size and Quantity 18 W × 1
UV Light Size and Quantity 20 W × 1
Illumination ≥900 LX
Cabinet Materials High-grade steel, lacquered in ivory
Working Area Materials SS304 fully finished
Air Direction Top out
Noise Level <65 dB
Vibration <5 μm (center of tabletop)
Maximum Consumption (with spare socket) 1.65 KW
Rated Power (without spare socket) 0.33 KW
Power Supply 115/230 V ±10%, 50/60 Hz
Internal Dimensions 1380 × 580 × 798 mm
External Dimensions 1500 × 810 × 2290 mm
Support Base (with wheels) 1485 × 710 × 670 mm
Weight 308 kg

Features

  • ULPA filtration efficiency >99.9995% at 0.12 µm particle size
  • Inflow velocity 0.55 m/s with vertical downflow velocity 0.35 m/s
  • ISO 4 Class air cleanliness with top exhaust airflow configuration
  • DC brushless airflow fan with smart power failure memory
  • SS304 finished work zone with scheduled UV sterilization feature

Applications

FunctionImplementation
Operator Safety Assurance<10 CFU/time containment validation with controlled airflow
Sample Sterility Maintenance<5 CFU/time culture dish verification during processing
Cross Contamination Prevention<2 CFU/time separation performance under test conditions
Microbiology & Genetics WorkISO 4 clean airflow environment for routine research procedures

Related Models Of Class II Biological Safety Cabinet

Lab Expo Class II Biological Safety Cabinet supports controlled containment workflows where regulated airflow and HEPA filtration are required for safe biological handling. This class ii bsc operates with defined inflow and downflow air patterns, offering A2 or B2 configurations with recirculation or total exhaust as specified. Microprocessor controls manage airflow stability and monitoring, while stainless steel work surfaces, negative pressure containment, and integrated alarms ensure controlled, compliant operation for routine laboratory procedures.