0

Atomic Absorption Spectrophotometer 15A-AAS103

Atomic Absorption Spectrophotometer 15A-AAS103 comes with flame, graphite furnace and hydride generation system to meet different customer demand. It consist of 1800/mm reticle large are grating monochromator and titanium burner to improve the analysis efficiency and accuracy of the flame. Atomic Absorption spectrophotometer has manual 3 lamp holder configuration & 3 independent lamp power supply for analysis.

Price: $10068

Wavelength range 180 to 900 nm
Spectral Bandwidth 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm(5 steps with automatic changeover)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs / 30 min (Static)≤ ± 0.005 Abs / 30 mins (Dynamic)
Absorbance Range 0 - 4 A
Lamp holder ≤ 3 lamps automatic turret, automatic alignment
Lamp power supply mode pulsed power supply
Optical System large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit (Cu) 0.002 μg/mL
Detection Limit (Cu) 0.002 μg/mL
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5 %
Precision RSD ≤ 0.5 %
Ignition Type Microcomputer control, automatic ignition
Ignition Type Microcomputer control, automatic ignition
Gas Control Automatic gas control system
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
  • 1800 /mm reticle (dispersion rate) large area grating monochromator
    High performance hollow cathode lamp
    Titanium burner for the flame analysis
    Polymer automization chamber 
    Automatic analysis for sensitivity and reproducibility
    High precision automatic optical system
    Flame, graphite furnace operating mode can be switched automatically
    Light source 3 lamp holder
    Convenient data processing & sharing & printing
    Powerful software with automatic instrument and additional control

  • Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.