0
Table top spectrophotometer 15A-TTS102

Table top spectrophotometer 15A-TTS102

Table top spectrophotometer 15A-TTS102 is a high-performance spectrophotometer with upward test caliber (top port). The solid samples (paper sheets, cloth) can be placed directly on the measurement port & particles like pellets, tablets, powder (dye, food powder, chemical powder), paste (thick paste, opaque samples can be placed in a round shape plate & then in the mouth of the measurement unit. It is adopted with every test calibration ETC technology, where the standard whiteboards are included in the optical system for every measurement's reliable accuracy.

Price: $15300

Illumination System d/8 (Diffused lighting, 8° observation angle)
Optical Engine SCS optical engine (light splitting and integration system)
Calibration Technology ETC (real-time calibration technology)
Measurement Modes SCI (specular reflection included) & SCE (specular reflection excluded) simultaneous measurement
Size of Integrated Sphere 15.2 cm, alvan diffused reflection surface coating
Illumination Light Source CLED
Sensor Dual light path sensor array
Light Sources A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Wavelength Range 400-700 nm
Wavelength Interval 10 nm
Half Spectral Width 5 nm
Reflectivity Range & Resolution 0 to 200%, 0.01%
Measurement Apertures LAV: 2.54 cm (1 inch) MAV: 1.5 cm (0.6 inch) SAV: 0.75 cm × 1.0 cm (0.3 inch × 0.4 inch) VSAV: 0.3 cm × 0.8 cm (0.12 inch × 0.31 inch)
Measurement Time Interval 2 s
Measurement Time 2 s
Color Spaces CIE-Lab, LCh, Luv, XYZ, Yxy, Reflectance, Hunterlab, Munsell Mi, CMYK
Color Difference Formulas ΔEab, ΔECH, ΔEuv, ΔEcmc(2:1), ΔEcmc(1:1), ΔE94, ΔE*00, ΔEab(Hunter), 555 color classification
Other Colorimetric Indices WI (whiteness) (ASTM E313-10, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925, ASTM E313-00, ASTM E313-73) Tint (ASTM E313, CIE, Ganz) Metamerism index Milm, adhesive/changing color fastness, ISO illuminance, 8 gloss, A density, T density
Repeatability Light splitting reflectivity: standard deviation within 0.08% Color values: ΔE*ab ≤ 0.015 (After calibration, standard deviation of 30 measurements on test white board, 5-second intervals), Maximum: 0.03
Operating Temperature Range 0 to 45°C, relative humidity ≤ 80% (at 35°C), no condensation
Storage Temperature Range -25°C to 55°C, relative humidity ≤ 80% (at 35°C), no condensation
Displayed Data Sample color values, color difference values/graph, pass/fail results, color error tendency, color value simulation, measurement area display, history data color simulation, manual input standard sample, measurement report generation
Interface USB
Display 5-inch TFT touch screen
Data Storage 20,000 test results
Light Source Longevity 10 years, 3 million tests
Dimensions (L × W × H) 583 × 330 × 304 mm
Weight 18 kg
  • Dual light path spectral analysis technology 
    Manual fitting of white calibration board on measurement port
    Four measurement calibers, maximum is 25.4 mm
    Large display screen for easier measurement and settings 
    Flexible measurement fixtures 
    Simultaneously measures SCI and SCE 
    PC connection for data transmission, software, storage
    Reflection and transmission measurement
    Adjustable UV components (light source) percentage value

  • Accessories No.Name
    1Power cord
    2USB cable
    3Driving software
    4Color QC software
    5Black and white calibration tile
  • Table top spectrophotometer with multiple measuring calibers has applications in measurement of solid as well as liquid material at multiple calibration points.

Atomic Absorption Spectrophotometer