0
Plant Growth Chamber 250-PGC200

Plant Growth Chamber 250-PGC200

Price: $4020

Plant Growth Chamber 250-PGC200 provides wide temperature range of 0 to 50℃ without light and 10 to 50℃ with light. It offers advanced lighting control system, to effectively simulate day and night changes. With humidity range of 50 to 90 % RH, it replicates desired conditions with high accuracy. Equipped with alarms, they alert users about deviations in parameters, maximizing safety. They feature a large capacity and a user-friendly interface, enhancing easy operation.

Chamber Volume 250 L
Temperature Range Without lighting: 0 to 50℃ With lighting: 10 to 50℃
Temperature Stability ± 1 ℃
Temperature Uniformity ± 1.5 ℃
Ambient Temperature 5 to 35℃
Humidity Range 50 to 90 % RH
Humidity Accuracy ± 5 to 7 % RH
Lighting Intensity 0 to 12000 LX
Programmer Function Temperature, humidity, light intensity, can be set separately, and 30 programmers. Time range is 1 - 99 hours for each programmer
Shelves 3(PCS)
Display Resolution 0.1 ℃
Power Consumption 860 W
Power 220 V, 50 Hz
Interior Dimension (W × D × H) 580 × 510 × 835 mm
Exterior Dimension (W × D × H) 725 × 740 × 1550 mm
    • Large LCD display

    • Imported compressor 

    • Microprocessor for temperature control

    • Printer and computer connection

    • Insulated inner chamber

  • Our Plant Growth Chambers are used to study plant growth, germination, photosynthesis and breeding under controlled environments in agricultural research, botanical studies, biotechnology and pharmaceutical institutes.

Customer Reviews

Submit Your Review

Drug stability chamber

Ozone Test Chamber

Plant Growth Chamber

Salt Spray Test Chamber

Sand and Dust Test Chamber

Temperature and Humidity Test Chamber

UV Test Chamber

UV Test Chamber 24-UTC100

  • UV Temperature Range: 50°C to 75°C
  • Testing Capacity: 48 piece (75 x 150 mm); 50 piece (75x 150 mm)
  • Water Consumption: Distilled water, 8liters per day
  • Dimension(W x D x H): 137 x 53 x 136 cm

UV Test Chamber 24-UTC200

  • Temperature Range: RT + 100 °C to 850 °C
  • Humidity range: At 400 °C: R.H. is 40 % to 85 % / At 800 °C: R.H. is 30 % ~ 50 %
  • Testing Time: 20 hours
  • Testing Voltage: 120 V to 145 V (135 V)

UV Test Chamber 24-UTC201

  • Temperature Range: RT + 100 °C to 630 °C
  • Humidity range: 30 % to 85 % RH
  • Testing Time: 20 hours
  • Testing Voltage: 120 V to 145 V

Xenon Test Chamber

NBS smoke chamber

NBS Smoke Chamber 71-SC100

  • Electrical: 110V AC 60Hz / 230V AC 50Hz
  • Gas supply: The preferred fuel gas used in the test is a mixture of air & propane
    Propane: The flow needs to be capable of delivering 20ml/min at a minimum pressure of 5 KPa
  • Compressed air: The flow needs to be capable of delivering 750ml/min at a nominal pressure of 400 Kpa
  • Ambient temperature: Operating 10°C to 35°C

NBS Smoke Chmaber Upgrade 71A-SC100

  • Electrical: 230 volts AC 50 Hz
  • Fuse rating: Anti-Surge 10 amp fuse
  • Ambient temperature: Operating 10°C to 35°C
  • Apparatus dimension (W×H×D): 400 x 800 x 300 mm

Flame chamber

Flame Chamber 70-FC100

  • Electrical: 115 Volts AC 60Hz / 230 volts 50Hz
  • Ambient temperature: Operating 10°C to 35°C
  • Dimensions (W×H×D): 1.0m3 - 1500 x 826 x 1150 mm

Spread of Flame Apparatus 70-SFA100

  • Electrical: 230 Volts AC 50 Hz or 115 Volts AC 60 Hz
  • Gas supply: The radiant panel of the apparatus can burn propane or natural gas. Typical gas supply requirements are a flow of up to 0.8 litres/second at a supply pressure of 200 mm water gauge.
  • Air supply: Air supply of up to 10 litres/second and at a supply pressure of approximately 300 mm water gauge is required
  • Dimensions (W×H×D): The radiant panel has overall dimensions of approximately 480 mm by 280 mm

Vertical flammability test chamber

FAA Flammability Test Chamber 70-FFTC100

  • Electrical: 230 volts AC 50Hz, 2 Amp / 115volts AC 60Hz, 4 Amp
  • Ambient temperature: Operating 10°C to 35°C
  • Dimensions (W×H×D): 752x 832 x 330 mm
  • Packed weight: 60 Kg

Flammability Test Equipment 70-FTE100

  • Electrical: 230 volts AC 50Hz volts / 115volts AC 60Hz
  • Ambient temperature: Operating 10°C to 35°C
  • Dimensions (W×H×D): 390x 540 x 230 mm

Vertical Flammability Test Chamber 70-VFTC200

  • Electrical: 230 V AC 50Hz volts/ 115 V AC 60Hz
  • Ambient temperature: Operating 10˚C to 35˚C
  • Gas supply: Commercial grade methane of minimum purity of 99% at a pressure of 0.2 Bar (2.5 psi) nominal
  • Dimensions (W×H×D): 430 × 800 × 330 mm

Temperature Humidity Test Chamber