Atomic Absorption Spectrophotometer 15A-AAS102

Lab Expo Atomic Absorption Spectrophotometer 15A-AAS102is designed with the latest technology, can automatically accomplish safety ignition and reproducibility of the flame method. The graphic analysis system gives information on analysis of the whole process e.g. measured value, temperature, procedures, time, etc. It consist of hollow cathode lamp to improve the analysis efficiency and accuracy of the flame & deuterium lamp for background correction.

$38,261.00 $ 31884

Atomic Absorption Spectrophotometer 15A-AAS102 - Specifications

Wavelength range 180 to 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic)
Absorbance Range 0 - 4 A
Detector Imported photomultiplier tube
Lamp holder ≤ 6 lamps automatic turret, automatic alignment
Lamp power supply mode pulsed power supply
Optical System large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit (Cu) 0.002 μg/mL
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5 %
Ignition Type Microcomputer control, automatic ignition
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Power supply 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA
Power supply 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA

Atomic Absorption Spectrophotometer 15A-AAS102 - Key Features

  • 1800 lines/mm grating with full closed optical system
  • Titanium combustion head burner 50mm or 100mm options
  • Polymer explosion-proof spray chamber for atomization
  • Automatic analysis ensures sensitivity and reproducibility of flame method
  • Six lamp holder with automatic turret alignment
  • Powerful software provides automatic instrument and additional control

Atomic Absorption Spectrophotometer 15A-AAS102 - Applications

FunctionImplementation
Flame analysis labs50 mm or 100 mm general combustion head supports sample atomization
Quality control testingDetection Limit (Cu): 0.002 μg/mL enables trace metal quantification
Research laboratoriesWavelength range: 180 to 900 nm allows multi-element analysis
Clinical diagnosticsPrecision: RSD ≤ 0.5 % ensures repeatable measurement results
Industrial process monitoringNumber of repeated measurements: 1 to 99 facilitates batch sample evaluation

Atomic Absorption Spectrophotometer 15A-AAS102 - Catalog

Related Atomic Absorption Spectrophotometer

Lab Expo Atomic Absorption Spectrophotometer units are designed for elemental and trace metal analysis in chemical, environmental, and research applications. Models support absorption spectrometer testing with wavelength ranges from 180 to 900 nm, automatic spectral bandwidth switching, and high-precision aas spectrometer measurement.