Lab Expo Atomic Absorption Spectrophotometer 15A-AAS103 comes with flame, graphite furnace and hydride generation system to meet different customer demand. It consist of 1800/mm reticle large are grating monochromator and titanium burner to improve the analysis efficiency and accuracy of the flame. Atomic Absorption spectrophotometer has manual 3 lamp holder configuration & 3 independent lamp power supply for analysis.
$39,701.00 $ 33084
| Wavelength range | 180 to 900 nm |
| Spectral Bandwidth | 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm(5 steps with automatic changeover) |
| Wavelength accuracy | ≤ 0.15 nm |
| Wavelength repeatability | ± 0.1 nm |
| Baseline drift | ≤ ± 0.002 Abs / 30 min (Static)≤ ± 0.005 Abs / 30 mins (Dynamic) |
| Absorbance Range | 0 - 4 A |
| Lamp holder | ≤ 3 lamps automatic turret, automatic alignment |
| Lamp power supply mode | pulsed power supply |
| Optical System | large 1800 /mm grating ruling, full closed optical system |
| Atomization Chamber | Polymer explosion-proof spray chamber |
| Characteristic concentration (Cu) | 0.015 μg / mL / 1 % |
| Characteristic concentration (Cu) | 0.015 μg / mL / 1 % |
| Detection Limit (Cu) | 0.002 μg/mL |
| Detection Limit (Cu) | 0.002 μg/mL |
| Burner | Full titanium combustion head, 50 mm or 100 mm general combustion head |
| Burner | Full titanium combustion head, 50 mm or 100 mm general combustion head |
| Nebulizer | Atomizer efficient glass atomizer,can also be customized |
| Nebulizer | Atomizer efficient glass atomizer,can also be customized |
| Precision | RSD ≤ 0.5 % |
| Precision | RSD ≤ 0.5 % |
| Ignition Type | Microcomputer control, automatic ignition |
| Ignition Type | Microcomputer control, automatic ignition |
| Gas Control | Automatic gas control system |
| Gas Control | Automatic gas control system |
| Measurement | Flame method, Hydride generation-Atomic absorption method |
| Measurement | Flame method, Hydride generation-Atomic absorption method |
| Concentration calculation | Standard curve method(1 - 3 times curve), automatic fitting |
| Concentration calculation | Standard curve method(1 - 3 times curve), automatic fitting |
| The number of repeated measurements | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. |
| The number of repeated measurements | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. |
| Print results | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. |
| Print results | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. |
| Packing Dimension | 120 x 60 x 60 cm |
| Gross Weight | 120 kg |
Function Implementation Flame analysis labs 0 - 4 A absorbance range supports quantitative metal concentration measurement Hydride generation testing Wavelength range: 180 to 900 nm enables detection of arsenic, selenium and other elements Quality control batches Precision: RSD ≤ 0.5 % ensures repeatable analytical results across sample sets Clinical trace metal labs Detection Limit (Cu): 0.002 μg/mL facilitates low-level copper quantification in biological matrices Research method development Spectral Bandwidth: 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm allows optimization for diverse analyte lines
Lab Expo Atomic Absorption Spectrophotometer units are designed for elemental and trace metal analysis in chemical, environmental, and research applications. Models support absorption spectrometer testing with wavelength ranges from 180 to 900 nm, automatic spectral bandwidth switching, and high-precision aas spectrometer measurement.