Benchtop Water Hardness Meter 25-BWH100 Catalog

Download

Overview :

Lab Expo Benchtop Water Hardness Meter 25-BWH100 is equipped with a large backlit LCD, 2 to 5 points calibration with low to high concentration range. The calibration due reminder alerts user for calibration of the meter on regular basis. The System menu allows setting the 7 parameters like stability condition, auto-power off etc. It measure salts of calcium & other elements at mg/L, mmol/ scale which causes hardness water.

Specifications:
Water hardness range 0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L
Temperature range 0 to 105 °C
Temperature accuracy ± 0.5 °C
Calibration range Measured value ± 10 °C
Temperature compensation range 0 to 50 °C
Compensation mode Manual or automatic
Data hold function Manual or automatic endpoint detection
Reset function Yes
Stability condition Low or high
Calibration due 0 to 31 days
Memory Stores up to 500 sets of data
Output USB communication interface
Connector BNC
Battery life Approximately 150 hours
Power 3 × 1.5 V “AA” batteries
Dimension (L × W × H) 170 × 85 × 30 mm
Weight 1.5 kg

Features:

  • Digital LCD display with real-time measurement viewing
  • Two to five point calibration across low high concentration range
  • System menu configuration for seven operational parameters
  • Calibration due reminder alerts for regular meter maintenance
  • Automatic temperature compensation ensures accurate value tracking
  • Reset function restores default operational settings immediately

Applications:

FunctionImplementationWater quality labs0.05 mmol/L - 0.2 mol/L range measures calcium salts across low to high concentrationField testing sitesBattery life of 150 hours supports extended operation without power accessCalibration stations2 to 5 points calibration ensures accurate measurement traceabilityIndustrial process controlTemperature compensation from 0 to 50 °C maintains accuracy in variable environmentsData logging applicationsMemory stores up to 500 sets of data for comprehensive record keeping

Standard Accessories:

Water hardness electrode
Temperature probe
AA batteries
Carrying case

Optional Accessories:

Water hardness electrode range 0.00005 to 0.2 M