Lab Expo Benchtop Water Hardness Meter 25-BWH100 is equipped with a large backlit LCD, 2 to 5 points calibration with low to high concentration range. The calibration due reminder alerts user for calibration of the meter on regular basis. The System menu allows setting the 7 parameters like stability condition, auto-power off etc. It measure salts of calcium & other elements at mg/L, mmol/ scale which causes hardness water.
$3,293.00 $ 2744
| Water hardness range | 0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f |
| Accuracy | ± 1 % F.S. |
| Calibration points | 2 to 5 points |
| Calibration solution | 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L |
| Temperature range | 0 to 105 °C |
| Temperature accuracy | ± 0.5 °C |
| Calibration range | Measured value ± 10 °C |
| Temperature compensation range | 0 to 50 °C |
| Compensation mode | Manual or automatic |
| Data hold function | Manual or automatic endpoint detection |
| Reset function | Yes |
| Stability condition | Low or high |
| Calibration due | 0 to 31 days |
| Memory | Stores up to 500 sets of data |
| Output | USB communication interface |
| Connector | BNC |
| Battery life | Approximately 150 hours |
| Power | 3 × 1.5 V “AA” batteries |
| Dimension (L × W × H) | 170 × 85 × 30 mm |
| Weight | 1.5 kg |
Function Implementation Water quality labs 0.05 mmol/L - 0.2 mol/L range measures calcium salts across low to high concentration Field testing sites Battery life of 150 hours supports extended operation without power access Calibration stations 2 to 5 points calibration ensures accurate measurement traceability Industrial process control Temperature compensation from 0 to 50 °C maintains accuracy in variable environments Data logging applications Memory stores up to 500 sets of data for comprehensive record keeping
Water hardness electrode
Temperature probe
AA batteries
Carrying case
Water hardness electrode range 0.00005 to 0.2 M
Lab Expo Benchtop Water Hardness Meter units are used for determination of calcium and magnesium-based hardness in water samples across laboratory workflows. The range supports measurement across multiple hardness units including CaCO₃, CaO, mmol per liter, and degree scales. Systems include calibration, temperature compensation, and digital interfaces, suitable for water treatment analysis, boiler monitoring, and industrial quality control.