Gas chromatography system is equipped with superior quality, high-precision electronic flow/ pressure control system. This gas chromatograph system has accurate tracking design and accurate programmed heating control system for the furnace temperature. Incorporated with safe and reliable functions of self-ignition and hydrogen leakage self-protection.
| Chromatography column type | Capillary or Packed column |
| Chromatography column length | 100 to 300 mm |
| Chromatography column diameter | 0.2 to 0.5 mm |
| Temperature operating range | Higher than the room temperature of 5 °C to 450°CLiquid nitrogen cold trap: -80 °C to 400 °CDry ice cold trap: -55 °C to 400 °C |
| Maximum programmed heating speed | 120 °C/min |
| Programmed temperature steps | 7 steps |
| Temperature setting precision | 0.1 °C |
| Programmed heating rate | 0.1 to 120 º C/min (increment of 0.1°C) |
| The longest method run time | 999.99 min |
| Furnace dimension | 280 × 300 ×180 mm |
| Heating area | Six individual controlling heating areasMaximum temperature in auxiliary heating area: 300 °C |
| Detectors | Following detectors can be selected as per the requirement |
| FID | Maximum using temperature: 450 °CMinimum LOD: ≤ 2.5 pg C / s [n - C16]Linear dynamic range: 107 (± 10 %)Data collection frequency: Maximum 100 Hz |
| TCD | Maximum using temperature: 400 °CMinimum LOD: < 400 pg C3 H8 / ml(He)Linear dynamic range: 105 (± 5 %)Data collection frequency: Maximum 100 HzThe design of monofilament TCD and Micro-ECD |
| FPD | Maximum using temperature: 250 °CMinimum LOD: < 4 pg S / sec, < 1 pg P/secLinear dynamic range: > 103 (S), > 104 (P)Optional: 105 g S / g C, 106 g P / g C |
| ECD | Maximum using temperature: 400 °CType of gas compensation detector: 5 % methane, argon, nitrogenMinimum LOD: > 107 S, > 107 PLinear dynamic range: 5 × 105 Data collection frequency: Maximum 100 HzRadioactive source: < 12 mCi 63 Ni |
| NPD | Maximum using temperature: 450 °CMinimum LOD: < 0.2 pg N / sec, < 0.2 pg P / secMinimum LOQ: < 3 pg / secLinear dynamic range: 105 N, 105 P |
FunctionImplementationPharmaceutical and food quality testingPrecise temperature and flow control ensure reproducible analysisPetrochemical and oil refiningMulti-detector selection supports hydrocarbon profilingHigh-purity gas evaluationEPC control maintains stable carrier gas deliveryChemical industry supervisionWide heating range manages complex compound separationResearch laboratoriesProgrammable methods up to 999.99 min enable detailed analytical studies