Gas chromatography system is equipped with superior quality, high-precision electronic flow/ pressure control system. This gas chromatograph system has accurate tracking design and accurate programmed heating control system for the furnace temperature. Incorporated with safe and reliable functions of self-ignition and hydrogen leakage self-protection.
$20,534.00 $ 17112
| Chromatography column type | Capillary or Packed column |
| Chromatography column length | 100 to 300 mm |
| Chromatography column diameter | 0.2 to 0.5 mm |
| Temperature operating range | Higher than the room temperature of 5 °C to 450°C Liquid nitrogen cold trap: -80 °C to 400 °C Dry ice cold trap: -55 °C to 400 °C |
| Maximum programmed heating speed | 120 °C/min |
| Programmed temperature steps | 7 steps |
| Temperature setting precision | 0.1 °C |
| Programmed heating rate | 0.1 to 120 º C/min (increment of 0.1°C) |
| The longest method run time | 999.99 min |
| Furnace dimension | 280 × 300 ×180 mm |
| Heating area | Six individual controlling heating areas Maximum temperature in auxiliary heating area: 300 °C |
| Detectors | Following detectors can be selected as per the requirement |
| FID | Maximum using temperature: 450 °C Minimum LOD: ≤ 2.5 pg C / s [n - C16] Linear dynamic range: 107 (± 10 %) Data collection frequency: Maximum 100 Hz |
| TCD | Maximum using temperature: 400 °C Minimum LOD: < 400 pg C3 H8 / ml(He) Linear dynamic range: 105 (± 5 %) Data collection frequency: Maximum 100 Hz The design of monofilament TCD and Micro-ECD |
| FPD | Maximum using temperature: 250 °C Minimum LOD: < 4 pg S / sec, < 1 pg P/sec Linear dynamic range: > 103 (S), > 104 (P) Optional: 105 g S / g C, 106 g P / g C |
| ECD | Maximum using temperature: 400 °C Type of gas compensation detector: 5 % methane, argon, nitrogen Minimum LOD: > 107 S, > 107 P Linear dynamic range: 5 × 105 Data collection frequency: Maximum 100 Hz Radioactive source: < 12 mCi 63 Ni |
| NPD | Maximum using temperature: 450 °C Minimum LOD: < 0.2 pg N / sec, < 0.2 pg P / sec Minimum LOQ: < 3 pg / sec Linear dynamic range: 105 N, 105 P |
Function Implementation Pharmaceutical and food quality testing Precise temperature and flow control ensure reproducible analysis Petrochemical and oil refining Multi-detector selection supports hydrocarbon profiling High-purity gas evaluation EPC control maintains stable carrier gas delivery Chemical industry supervision Wide heating range manages complex compound separation Research laboratories Programmable methods up to 999.99 min enable detailed analytical studies
Lab Expo gas chromatography systems include excellent temperature management, offering numerous stages and a broad temperature range. They come with a variety of detectors that provide great sensitivity and stability. These devices have LCD screens and several injector choices. They provide dependability through self-diagnosis, data storage during power outages, and improved insulation. Our gas chromatography systems examine gas, solid, and liquid samples and return exact findings.