Gas Chromatography 30-GCG101

Gas chromatography system is equipped with superior quality, high-precision electronic flow/ pressure control system. This gas chromatograph system has accurate tracking design and accurate programmed heating control system for the furnace temperature. Incorporated with safe and reliable functions of self-ignition and hydrogen leakage self-protection.

$20,534.00 $ 17112

Gas Chromatography 30-GCG101 - Specifications

Chromatography column type Capillary or Packed column
Chromatography column length 100 to 300 mm
Chromatography column diameter 0.2 to 0.5 mm
Temperature operating range Higher than the room temperature of 5 °C to 450°C
Liquid nitrogen cold trap: -80 °C to 400 °C
Dry ice cold trap: -55 °C to 400 °C
Maximum programmed heating speed 120 °C/min
Programmed temperature steps 7 steps
Temperature setting precision 0.1 °C
Programmed heating rate 0.1 to 120 º C/min (increment of 0.1°C)
The longest method run time 999.99 min
Furnace dimension 280 × 300 ×180 mm
Heating area Six individual controlling heating areas
Maximum temperature in auxiliary heating area: 300 °C
Detectors Following detectors can be selected as per the requirement
FID Maximum using temperature: 450 °C
Minimum LOD: ≤ 2.5 pg C / s [n - C16]
Linear dynamic range: 107 (± 10 %)
Data collection frequency: Maximum 100 Hz
TCD Maximum using temperature: 400 °C
Minimum LOD: < 400 pg C3 H8 / ml(He)
Linear dynamic range: 105 (± 5 %)
Data collection frequency: Maximum 100 Hz
The design of monofilament TCD and Micro-ECD
FPD Maximum using temperature: 250 °C
Minimum LOD: < 4 pg S / sec, < 1 pg P/sec
Linear dynamic range: > 103 (S), > 104 (P)
Optional: 105 g S / g C, 106 g P / g C
ECD Maximum using temperature: 400 °C
Type of gas compensation detector: 5 % methane, argon, nitrogen
Minimum LOD: > 107 S, > 107 P
Linear dynamic range: 5 × 105
Data collection frequency: Maximum 100 Hz
Radioactive source: < 12 mCi 63 Ni
NPD Maximum using temperature: 450 °C
Minimum LOD: < 0.2 pg N / sec, < 0.2 pg P / sec
Minimum LOQ: < 3 pg / sec
Linear dynamic range: 105 N, 105 P

Gas Chromatography 30-GCG101 - Key Features

  • Electronic flow and pressure control with EPC regulated injector and carrier gas flow
  • Operating temperature above RT up to 450 C with 0.1 C precision and 120 C/min heating rate
  • Seven-step temperature programming with six independently controlled heating areas
  • Self-ignition function with hydrogen leakage self-protection
  • Selectable detectors including FID, TCD, FPD, ECD and NPD

Gas Chromatography 30-GCG101 - Applications

FunctionImplementation
Pharmaceutical and food quality testingPrecise temperature and flow control ensure reproducible analysis
Petrochemical and oil refiningMulti-detector selection supports hydrocarbon profiling
High-purity gas evaluationEPC control maintains stable carrier gas delivery
Chemical industry supervisionWide heating range manages complex compound separation
Research laboratoriesProgrammable methods up to 999.99 min enable detailed analytical studies

Gas Chromatography 30-GCG101 - Catalog

Related Gas Chromatography

Lab Expo gas chromatography systems include excellent temperature management, offering numerous stages and a broad temperature range. They come with a variety of detectors that provide great sensitivity and stability. These devices have LCD screens and several injector choices. They provide dependability through self-diagnosis, data storage during power outages, and improved insulation. Our gas chromatography systems examine gas, solid, and liquid samples and return exact findings.