Real-Time PCR 62-RTP202 Catalog

Download

Overview :

Lab Expo Real-Time PCR 62-RTP202 comes with 96 well capacity PCR machine with, 1 to 36°C gradient temperature range, and fast speed dual colour scanning mode. Its wide fluorescence wavelength range with innovative 6 channel design, optimizes thermal performance and maximizes convenience during operation. With its unique block dissipation technology, it provides precise temperature control and thermal gradient which easily optimizes PCR assays.

Specifications:
Sample Capacity 96-Well PCR plate12 × 8-strip 96 × 0.2 ml(Bottom Transparent)
Emission Wavelength 500 to 800 nm
Excitation Wavelength 300 to 800 nm
Sample Volume Range 5 to 100μl
Program Max 20 Segments for Each Program, Max 99 Cycles
Dynamics Range 10 to 1010 Copies
Max. channels number of fluorescence detection 6 channels
Detected Fluorescence F1 : FAM SYBR Green I;F2 : VIC HEX TET JOE; F3 : CY3 NED TAMRA; F4 : ROX TEXAS-RED;F5 : Cy5;F6 : ht cycler red
Block Temp. Range 4 to 105℃ (Minimum Increment: 0.1℃), SOAK Low Temp. Conservation Function
Temp. Control Accuracy ≤ ± 0.1 ℃
Temp. Fluctuation ≤ ± 0.1 ℃
Temp. Uniformity ≤ ± 0.3 ℃
Ramping Rate 4.0 ℃/sec
Temp. Control Mode BLOCK/Tube Simulation Mode (Automatic Control based On Sample Volume )
Gradient Temp. Range 1 to 36 ℃
Hot-lid Temp. Range 30 to 110℃ (Adjustable, default 105℃, Automatic Hot-lid )
Fluorescence DetectionRepeatability 0.05
Operation Mode Continuous
Scan Mode Entire Plate or Designated Line
Scan Period 5.5 sec
Operation System Microsoft: Windows2000/XP/vista/Windows7Software: Excel2003/2007 Access: 2003/2007
PC Configuration Memory : 512 M; Hard Disk : 10 GB; CPU : Pentium® 4; Virtual Memory : ≥ 1000 MB
Power Supply 100 to 240 V, 50/60 Hz, 600 W
Dimension ( L × W × H ) 430 x 395 x 352 mm
Socket RS 232C Adapter

Features:

  • Ferrotec Peltier cooler with 600W power supply and long life operation
  • Block temperature range 4 to 105C with SOAK low temperature function
  • Six individual filters covering fluorescence detection wavelength 300 to 800 nm
  • USB and Bluetooth data transfer for seamless experimental result export
  • Real-time fast double wavelength X-Y scan system at 5.5 second period
  • High long life LED with dual high sensitivity PMT synchronous detection

Applications:

FunctionImplementationClinical diagnostics labs6 channels enables multiplex fluorescence detectionResearch laboratories±0.1℃ accuracy supports precise thermal controlQuality control facilities96-well capacity processes high sample volumesIndustrial testing environments4.0℃/sec ramping rate accelerates cycle timesEducational institutions5 to 100μl volume range accommodates varied assays

www.labexpo.com