Biological Safety Cabinet 99-BSC102

Biological Safety Cabinet 99-BSC102 uses a ULPA filter with >99.9995% efficiency to capture particles as small as 0.12μm for maximum protection. It has a downflow velocity of 0.35m/s for even airflow and an inflow velocity of 0.55m/s to safely contain hazardous materials. It has a DC brushless fan that maintains optimal airflow for safety while operating quietly and efficiently. It features a sterilization function to sanitize surfaces and airflow paths, keeping the workspace free from contaminants for safe operation.

$8,981.00 $ 7484

Specifications

Filtration efficiency >99.9995% at 0.12μm
Down flow velocity 0.35m/s
Inflow velocity 0.55m/s
Air supply and exhaust filters ULPA filters
Air Cleanliness ISO 4 Class
Execution standards YY0569(GB 4793.1、GB/T 18268.1)
Personnel Protection Total colony in impaction sampler <10CFU. /Time B. Total colony in slot sampler <5CFU. /Time
Product Protection Total colony in culture dish <5CFU. /Time
Cross-contamination Protection Total colony in culture dish <2CFU. /Time
Size and Qty. of Light 18W×1
Size and Qty. of UV Light 20W×1
Lumin. ≥900LX
Cabinet Materials High-grade steel and lacquered in ivory
Working Area Materials SS304 fully finished
Air Direction Top out
Noise level <65 dB
Vibration <5μm (center of tabletop)
Max Power Consumption (with spare socket) 1.65KW
Rated Power (without spare socket) 0.33KW
Power supply 115/230V±10%, 50/60Hz
Internal Dimensions 1680×580×798mm
External Dimension 1800×810×2290mm
Support base (with wheel) 1800×710×645mm
Weight 375kg

Features

  • Inflow velocity 0.55 m/s with uniform 0.35 m/s vertical downflow
  • ISO 4 Class air cleanliness with top exhaust airflow direction
  • High-efficiency DC brushless fan with power failure memory function
  • SS304 finished work surface with integrated UV sterilization system

Applications

FunctionImplementation
Operator Protection Assurance<10 CFU/time impaction & <5 CFU/time slit sampler validation
Sample Sterility Maintenance<5 CFU/time culture dish verification during handling
Cross Contamination Control<2 CFU/time separation performance under validated testing
Microbiology & Gene ResearchISO 4 classified controlled airflow environment
Clinical & Pharmaceutical WorkflowsULPA-filtered sterile workspace for diagnostic & production tasks

Related Models Of Class II Biological Safety Cabinet

Lab Expo Class II Biological Safety Cabinet supports controlled containment workflows where regulated airflow and HEPA filtration are required for safe biological handling. This class ii bsc operates with defined inflow and downflow air patterns, offering A2 or B2 configurations with recirculation or total exhaust as specified. Microprocessor controls manage airflow stability and monitoring, while stainless steel work surfaces, negative pressure containment, and integrated alarms ensure controlled, compliant operation for routine laboratory procedures.