Lab Expo PMCC Flash Point Tester 52-CFP100 offers a wide temperature range of 5°C to 370°C with scale divisions of 0.5°C, 1°C, and 2°C. Featuring an adjustable stirring speed, it ensures uniform temperature distribution throughout the fluid. It includes a 70 ml capacity oil cup to hold sufficient sample volume. Equipped with a 0.8 mm aperture ignition device, it ensures precise flash point determination. This tester uses coal gas as ignition source to deliver precise results.
$5,669.00 $ 4724
Specifications
| Temperature Range | 5 °C to 110 °C, each scale division is 0.5 °C 20 °C to 150 °C, each scale division is 1.0 °C 90 °C to 370 °C, each scale division is 2 °C |
| Aperture of Ignition Device | 0.8 mm |
| Standard Oil Cup-Inner Diameter | 50.7 to 50.8 mm |
| Standard Oil Cup- Depth | 55.7 to 56.0 mm |
| Standard Oil Cup- Depth of Marked Line on the Oil Cup | 33.9 to 34.3 mm |
| Standard Oil Cup-Oil Sample Cubage | About 70 ml |
| Stirring Speed | 90 to 120 rpm for procedure A; 250 ± 10 rpm for procedure B |
| Stirring Blade (L×W) | 8 × 40 mm |
| Sample Temperature Rising Rate | 1 to 12 °C per minute |
| Ambient Temperature | ≤ 35 °C |
| Relative Humidity | ≤ 85 % |
| Heating Power | 0 to 600 W |
| Total Power Consumption | 600 W |
| Heating Power | 0 to 600 W |
| Total Power Consumption | 600 W |
| Power Supply | AC 220 V ± 10 %, 50 Hz |
| Power Supply | AC 220 V ± 10 %, 50 Hz |
| Dimension (L×W×H) | 480×420×440 mm |
| Net Weight | 7 kg |
| Gross Weight | 13 kg |
Features
Applications
Function Implementation Quality control labs 600 W heating power supports consistent sample analysis Petroleum testing facilities 70 ml oil cup capacity accommodates standard sample volumes Clinical research settings 5°C to 370°C temperature range enables diverse fluid evaluation Industrial safety departments 90 to 120 rpm stirring speed ensures uniform thermal distribution Educational training units ±10% AC 220 V power supply allows stable laboratory operation
Lab Expo Closed Cup Flash Point Tester units are used for determination of flash point of flammable liquids under controlled enclosed conditions in laboratory workflows. The range supports testing from approximately 5 °C to 400 °C with defined resolution and repeatability. Systems integrate controlled heating, automated ignition, and sample stirring, suitable for petroleum testing, chemical analysis, and safety compliance applications.