Lab Expo PMCC Flash Point Tester 52-CFP100 offers a wide temperature range of 5°C to 370°C with scale divisions of 0.5°C, 1°C, and 2°C. Featuring an adjustable stirring speed, it ensures uniform temperature distribution throughout the fluid. It includes a 70 ml capacity oil cup to hold sufficient sample volume. Equipped with a 0.8 mm aperture ignition device, it ensures precise flash point determination. This tester uses coal gas as ignition source to deliver precise results.

$5,669.00 $ 4724

Specifications

Temperature Range 5 °C to 110 °C, each scale division is 0.5 °C
20 °C to 150 °C, each scale division is 1.0 °C
90 °C to 370 °C, each scale division is 2 °C
Aperture of Ignition Device 0.8 mm
Standard Oil Cup-Inner Diameter 50.7 to 50.8 mm
Standard Oil Cup- Depth 55.7 to 56.0 mm
Standard Oil Cup- Depth of Marked Line on the Oil Cup 33.9 to 34.3 mm
Standard Oil Cup-Oil Sample Cubage About 70 ml
Stirring Speed 90 to 120 rpm for procedure A; 250 ± 10 rpm for procedure B
Stirring Blade (L×W) 8 × 40 mm
Sample Temperature Rising Rate 1 to 12 °C per minute
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Heating Power 0 to 600 W
Total Power Consumption 600 W
Heating Power 0 to 600 W
Total Power Consumption 600 W
Power Supply AC 220 V ± 10 %, 50 Hz
Power Supply AC 220 V ± 10 %, 50 Hz
Dimension (L×W×H) 480×420×440 mm
Net Weight 7 kg
Gross Weight 13 kg

Features

  • 45TYZ stirring motor with 90 to 120 rpm speed
  • Mercury thermometer measuring temperature with 0.5C resolution
  • Rod type ignition device featuring 0.8 mm aperture
  • User-friendly interface supporting wide temperature range
  • Compact and durable design with 600 W power consumption

Applications

FunctionImplementation
Quality control labs600 W heating power supports consistent sample analysis
Petroleum testing facilities70 ml oil cup capacity accommodates standard sample volumes
Clinical research settings5°C to 370°C temperature range enables diverse fluid evaluation
Industrial safety departments90 to 120 rpm stirring speed ensures uniform thermal distribution
Educational training units±10% AC 220 V power supply allows stable laboratory operation

Related Models Of Closed Cup Flash Point Tester

Lab Expo Closed Cup Flash Point Tester units are used for determination of flash point of flammable liquids under controlled enclosed conditions in laboratory workflows. The range supports testing from approximately 5 °C to 400 °C with defined resolution and repeatability. Systems integrate controlled heating, automated ignition, and sample stirring, suitable for petroleum testing, chemical analysis, and safety compliance applications.