0
Spread of Flame Apparatus 70-SFA100

Spread of Flame Apparatus 70-SFA100

70-SFA100 Spread of Flame Apparatus measures the flame spread of the materials. The IMO marine specification includes a collection hood for heat release measurement. The apparatus is constructed depending on the requirements of the standard and essentially two main items, the radiant panel framework and the specimen support framework, and many supplementary items.

Electrical 230 Volts AC 50 Hz or 115 Volts AC 60 Hz
Gas supply The radiant panel of the apparatus can burn propane or natural gas. Typical gas supply requirements are a flow of up to 0.8 litres/second at a supply pressure of 200 mm water gauge.
Air supply Air supply of up to 10 litres/second and at a supply pressure of approximately 300 mm water gauge is required
Dimensions (W×H×D) The radiant panel has overall dimensions of approximately 480 mm by 280 mm
  • The panel is manufactured from all-welded square tubular with mild steel material and includes all the associated pipework and control valves for the radiant panel
    The panel consists of porous refractory tiles mounted in a stainless steel housing and it is mounted on the support framework on a rotating steel ring which allows the specimen for the testing in different orientations
    It is designed for use with natural gas or propane gas and the gas is mixed with air before entry to the panel
    The pressure governors and control, it has shut off valve for both gas and the air
    Integrated with variable area flowmeters in the pipework to allow the gas and air to the radiant panel to be controlled and monitored
    Consist fixed control box to the framework which contains indicators of lamps and push-buttons associated with the gas safety system
    The framework which supports the test specimen is made from all-welded square tubular mild steel sections
    One side of the framework contains a steel guide which carries the specimen holder
    In the test position, the surface of the specimen at the end of adjacent to the radiant panel is brought close to a test flame from a stainless steel tube fixed to the support frame and supplied with gas/air mixture from the main gas supplies on the radiant panel support framework
    The heat release stack us mounted on the specimen support framework and directly above the test specimen, such that the combustion products rising from a vertically mounted specimen are channelled into the stack
    The specimen support framework is connected to the support frame for the radiant panel by the spacer and fixing bolts
    The stainless steel specimen holder is constructed according to the requirements and specifications
    A spring-type loaded quick action clamp for easy loading and retention of the test specimen is also provided
    It has a calibration board and a heat flux meter
    The calibration board is made with calcium silicate-based board material and is provided with a series of holes, when the calibration board is inserted into the test apparatus, positions the heat flux meter at prescribed calibration locations
    The output from the meter can be monitored on a suitable recording device or from the optional data acquisition and software system
    It consists specially designed device which enables the outputs from the thermocouple on the heat release stack to be conditioned as required based on the specification
  • The Spread of Flame Apparatus measures the flame spread of materials in marine and railway applications

Customer Reviews

Submit Your Review

Drug stability chamber

Ozone Test Chamber

Plant Growth Chamber

Salt Spray Test Chamber

Sand and Dust Test Chamber

Temperature and Humidity Test Chamber

UV Test Chamber

UV Test Chamber 24-UTC100

  • UV Temperature Range: 50°C to 75°C
  • Testing Capacity: 48 piece (75 x 150 mm); 50 piece (75x 150 mm)
  • Water Consumption: Distilled water, 8liters per day
  • Dimension(W x D x H): 137 x 53 x 136 cm

UV Test Chamber 24-UTC200

  • Temperature Range: RT + 100 °C to 850 °C
  • Humidity range: At 400 °C: R.H. is 40 % to 85 % / At 800 °C: R.H. is 30 % ~ 50 %
  • Testing Time: 20 hours
  • Testing Voltage: 120 V to 145 V (135 V)

UV Test Chamber 24-UTC201

  • Temperature Range: RT + 100 °C to 630 °C
  • Humidity range: 30 % to 85 % RH
  • Testing Time: 20 hours
  • Testing Voltage: 120 V to 145 V

Xenon Test Chamber

NBS smoke chamber

NBS Smoke Chamber 71-SC100

  • Electrical: 110V AC 60Hz / 230V AC 50Hz
  • Gas supply: The preferred fuel gas used in the test is a mixture of air & propane
    Propane: The flow needs to be capable of delivering 20ml/min at a minimum pressure of 5 KPa
  • Compressed air: The flow needs to be capable of delivering 750ml/min at a nominal pressure of 400 Kpa
  • Ambient temperature: Operating 10°C to 35°C

NBS Smoke Chmaber Upgrade 71A-SC100

  • Electrical: 230 volts AC 50 Hz
  • Fuse rating: Anti-Surge 10 amp fuse
  • Ambient temperature: Operating 10°C to 35°C
  • Apparatus dimension (W×H×D): 400 x 800 x 300 mm

Flame chamber

Flame Chamber 70-FC100

  • Electrical: 115 Volts AC 60Hz / 230 volts 50Hz
  • Ambient temperature: Operating 10°C to 35°C
  • Dimensions (W×H×D): 1.0m3 - 1500 x 826 x 1150 mm

Vertical flammability test chamber

FAA Flammability Test Chamber 70-FFTC100

  • Electrical: 230 volts AC 50Hz, 2 Amp / 115volts AC 60Hz, 4 Amp
  • Ambient temperature: Operating 10°C to 35°C
  • Dimensions (W×H×D): 752x 832 x 330 mm
  • Packed weight: 60 Kg

Flammability Test Equipment 70-FTE100

  • Electrical: 230 volts AC 50Hz volts / 115volts AC 60Hz
  • Ambient temperature: Operating 10°C to 35°C
  • Dimensions (W×H×D): 390x 540 x 230 mm

Vertical Flammability Test Chamber 70-VFTC200

  • Electrical: 230 V AC 50Hz volts/ 115 V AC 60Hz
  • Ambient temperature: Operating 10˚C to 35˚C
  • Gas supply: Commercial grade methane of minimum purity of 99% at a pressure of 0.2 Bar (2.5 psi) nominal
  • Dimensions (W×H×D): 430 × 800 × 330 mm

Temperature Humidity Test Chamber