Cold Filter Plugging Point Filter 52-LTT102

Cold Filter Plugging Point Filter 52-LTT102

Lab Expo Cold Filter Plugging Point Filter 52-LTT102 determines the temperature at which diesel and distillate fuels begin to plug filters under low-temperature conditions. It features a round glass sample cup with inner diameter of 31.0 to 32.0 mm for consistent fuel flow testing. The unit operates within an ambient temperature range of -10℃ to 35℃ and relative humidity up to 85%. Designed for quality control in petroleum, chemical, and industrial laboratories, it supports reliable cold flow property assessment for procurement teams evaluating fuel performance specifications.

$4,762.00 $ 3968

Cold Filter Plugging Point Filter 52-LTT102 - Specifications

Ambient temperature (-10)℃ to 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 to 32.0 mm
Sample cup Wall thickness 1.0 to 1.5 mm
Sample cup Height 115 to 125 mm
Pumping pressure U type differential pressure meter 1961 Pa (200 mm H2O)
Total power consumption ≤ 150 W
Power supply AC 220 V ± 10 %, 50 Hz

Cold Filter Plugging Point Filter 52-LTT102 - Key Features

  • Relative low temperature tester with 100C operating range
  • Round glass cup sample chamber 31.5mm inner diameter
  • Equipped with SH/T0248 test method compliance standard
  • Advance digital display with 0.1C resolution accuracy
  • Integrated structure design for stable operation

Cold Filter Plugging Point Filter 52-LTT102 - Applications

FunctionImplementation
Quality control labs≤ 150 W powers consistent CFPP testing operations
Clinical fuel analysisAC 220 V ± 10 %, 50 Hz ensures stable lab power input
Research facilitiesU type differential pressure meter 1961 Pa enables precise flow measurement
Industrial testing sitesSample cup Height: 115 to 125 mm supports standardized sample handling
Institutional laboratoriesAmbient temperature: (-10)℃ to 35 ℃ allows operation in varied environments

Cold Filter Plugging Point Filter 52-LTT102 - Catalog

Related Low Temperature Tester

Lab Expo Low Temperature Tester units are configured for evaluation of pour point, cloud point, freezing point, solidifying point, and cold filter plugging characteristics in petroleum testing workflows. Systems support controlled low-temperature operation down to -80 °C with refrigeration-based cooling and temperature accuracy up to ±0.5 °C. Available configurations integrate multi-bath cold trough systems, automated refrigeration control, and stability testing functions for lubricant, fuel, and oil quality assessment applications.