Microspectrophotometer LE-MS101

Lab Expo Microspectrophotometer LE-MS101 is optimized for measuring ultra-low sample volumes ranging from 0.5 to 2 µl with high precision. It offers optical path conversion between 1.2 mm, 1.0 mm, and 0.2 mm for enhanced flexibility across sample types. Equipped with a broad wavelength for accurate readings across the spectrum. Our Microspectrophotometer delivers dependable performance in a compact and user-friendly design for modern lab workflows.

$6,936.00 $ 5780

Microspectrophotometer LE-MS101 - Specifications

Sample Volume 0.5 to 2 µl
Path Length 0.2mm, 1.0m, 1.2mm
Wavelength 180 to 910 nm
Wavelength Accuracy ± 1 nm
Wavelength Precision ± 0.2 nm
Absorbance Accuracy ±1%(7.332 Abs at 260nm)
Absorbance Precision 0.002Abs
Absorbance Range 0.04 to 90 A (equaled 10mm)
Spectral Resolution ≤ 1.5nm(FWHM @ Hg 253.7nm)
Nucleic Acid Detection Range dsDNA: 2 to 4500ng/µL ssDNA:1.32 to 2970ng/ µL RNA:1.6 to 3600ng/ µL
Protein Detection Range A280: 0.04 to 80.4mg/m1BSA: 400mg/mlIgG: 290mg/mlLysozyme: 0.026 to 30.5mg/ml
Sample Pedestal 304 Stainless Steel and Quartz Fiber
Data Export USB
Light Source Xenon Lamp
Detector 2048 -Element Linear Silicon CMOS Array
Measurement Time < 6 seconds
Power Adapter 12 V 4 A
Power Consumption 48W (working) /
Dimension 270 × 210 × 196 mm
Weight 3.3 kg

Microspectrophotometer LE-MS101 - Key Features

  • Auto-Calibration ensures measurement consistency with 0.2 nm wavelength precision
  • Quick Detection Time delivers results in under 6 seconds for rapid analysis
  • CMOS Array Detector features 2048-element linear silicon sensor for spectral capture
  • Robust Design incorporates xenon lamp light source with 180 to 910 nm wavelength range

Microspectrophotometer LE-MS101 - Applications

FunctionImplementation
Ultra-low volume samples0.5 to 2 µl enables precise micro-volume analysis
Protein quantification rangeA280: 0.04 to 80.4 mg/ml supports accurate concentration measurement
Rapid spectral scanning<6 seconds allows high-throughput sample processing
Broad wavelength coverage180 to 910 nm facilitates diverse biomolecule detection
Compact benchtop use270 × 210 × 196 mm fits space-constrained laboratory setups

Microspectrophotometer LE-MS101 - Standard Accessories

  • Power Adapter
  • U Disk
  • Dust Cover
  • QC Pass Card

Microspectrophotometer LE-MS101 - Catalog


Microspectrophotometer LE-MS101

Microspectrophotometer LE-MS101

Related Microspectrophotometer

Lab Expo Microspectrophotometer units are designed for micro-volume absorbance analysis in molecular biology, clinical, and forensic applications. Models support micro spectrophotometer testing with 0.5 to 2 µl sample volumes and 180 to 910 nm wavelength range for nucleic acid, protein, and microspectrophotometer forensics analysis.