Nano Spectrophotometer 15A-NSP300

Lab Expo Nano Spectrophotometer 15A-NSP300 with full spectrum covers a wide wavelength range of 190 to 850 nm. It requires only 0.3 - 2 µl sample for measurement which takes place within 5 seconds. It uses Xenon flash lamp as light source which has high stability and long operating life. It has built in Computer, screen & four USB interface. Nano spectrophotometer connected to mouse, printer, and other wireless card devices for multiple operations.

$10,500.00 $ 8750

Nano Spectrophotometer 15A-NSP300 - Specifications

Cuvette No
PC Inbuilt
Wavelength range 190 to 850 nm
Path length 1 mm, 0.2 mm ,0.04 mm
Wavelength accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Path length of cuvette 1 mm/2 mm/5 mm/10 mm
Minimum Sample size 0.3 to 2.0 µl
Absorbance range 0.002 to 75 A (150,300 optional, 10 mm equivalent absorbance)
Precision of wavelength ± 1 nm
Absorbance precision 0.002 to 400 Abs (10 mm)
Absorbance accuracy 1 % (0.76 absorbance at 350 nm)
Light source Xenon flash lamp
Measurement time < 5 s
Sample Pedestal Material Stainless steel and quartz fiber
Detector Type 2048-element linear silicon CCD
Screen Color LCD Touchscreen display
Software Compatibility Win7 (64-bit operating system)/Win 8
Detects nucleic acid up to 0.4 to 19000 ng/µL (dsDNA)
Detects protein up to 0.01 to 400 mg/mL (BSA)
Dimension 350 x 240 x 220 mm
Weight 5.2 kg

Nano Spectrophotometer 15A-NSP300 - Key Features

  • Wavelength range 190 to 850 nm with ±1 nm accuracy
  • Minimum sample size 0.3 to 2.0 microliters for analysis
  • Path length options 1 mm, 0.2 mm, and 0.04 mm available
  • Measurement time under five seconds per sample cycle
  • Detector type: linear silicon CCD with high sensitivity detection
  • Absorbance accuracy one percent at specified calibration points

Nano Spectrophotometer 15A-NSP300 - Applications

FunctionImplementation
Nucleic acid quantification0.4 to 19000 ng/µL dsDNA detection enables sensitive sample analysis
Protein concentration assays0.01 to 400 mg/mL BSA range supports accurate biomolecule measurement
Ultra-low volume testing0.3 to 2.0 µl minimum sample size facilitates precious specimen use
Rapid wavelength scanning<5 s measurement time allows high-throughput workflow integration
Visible and UV analysis190 to 850 nm wavelength range covers standard analytical methods

Nano Spectrophotometer 15A-NSP300 - Catalog

Related Nano spectrophotometer

Lab Expo Nano Spectrophotometer units are designed for low-volume nucleic acid and protein analysis in molecular biology and research applications. Models support microvolume spectrophotometer testing with wavelength ranges from 190 to 900 nm, sample sizes as low as 0.3 µL, and automatic path length switching for nano photometer analysis.