Sample Concentrator LE-SC201

Sample Concentrator LE-SC201

Lab Expo Sample Concentrator LE-SC201 supports a wide temperature range from 5°C to 160°C for different sample types. Equipped with an independent nitrogen blowing system for smooth and efficient evaporation. Built in automatic fault detection and temperature deviation calibration system enhances operational accuracy. Our Sample Concentrator is designed to meet demanding laboratory protocols with reproducible results.

$2,155.00 $ 1796

Sample Concentrator LE-SC201 - Specifications

Temperature Range 0℃ to 160℃
Temperature Control Range 5℃ to 160℃
Block Quantity 1
Time Range 1min to 99min 59sec
Temperature Accuracy ± 0.5℃ (at 40℃)± 1℃ (at 120℃)
Temperature Uniformity ± 0.5℃
Display Accuracy 0.1℃
Heating Time ≤ 15 min
Maximum Vertical Travel 200 mm
Nitrogen Flow Rate 15 L/min
Nitrogen Pressure 0.1 MPa
Power Consumption 300W
Power Supply AC 220/110V, 50/60 Hz
Dimension 260 × 220 × 475
Weight 6.0 Kg

Sample Concentrator LE-SC201 - Key Features

  • Nitrogen pressure control at 0.1MPa for consistent evaporation
  • LED display panel with 0.1C resolution accuracy
  • Heating time completion within 15 minutes maximum
  • Block quantity single unit for focused processing
  • Maximum vertical travel distance of 200mm adjustment range
  • Time range programmable from 1min to 99min59sec duration

Sample Concentrator LE-SC201 - Applications

FunctionImplementation
Sample preparation labs0℃ to 160℃ temperature range enables evaporation of diverse solvents
Clinical diagnostics±0.5℃ accuracy at 40℃ ensures precise thermal control for biological samples
Quality control testing≤15 min heating time supports rapid sample throughput in QC workflows
Research laboratories15 L/min nitrogen flow rate facilitates efficient solvent removal from multiple samples
Industrial processingMaximum vertical travel of 200 mm accommodates various tube sizes in production settings

Sample Concentrator LE-SC201 - Optional Accessories

Block – 10mm × 12

Block – 12mm × 12

Block – 13mm × 12

Block – 15mm × 12

Block – 16mm × 12

Block – 19mm × 12

Block – 20mm × 12

Flow control valve

Sample Concentrator LE-SC201 - Catalog

Sample Concentrator LE-SC201 FAQ's

1: What temperature range does Sample Concentrator LE-SC201 support?

LE-SC201 is used for nitrogen-assisted sample evaporation in laboratories handling residue analysis, pharmaceuticals, food safety, biological samples, environmental testing, and chemical analysis.

2: How is nitrogen used in the concentration process?

Our system includes an independent nitrogen blowing system that enables controlled and efficient evaporation by delivering nitrogen gas directly to the sample surface.

3: What is the heating time for the system?

Our system reaches the set temperature in 15 minutes or less, ensuring rapid operation.

4: Does it include any alarm or safety features?

Yes, it includes an alarm function, automatic fault detection, and temperature deviation calibration for safe and reliable operation.

5: What is the time range for operation?

Our Sample Concentrator can be programmed to operate between 1 minute to 99 minutes 59 seconds, depending on the evaporation needs.

6: What type of samples can be processed with this concentrator?

It is ideal for residue analysis, pharmaceutical quality control, food safety testing, chemical analysis, biological samples, and environmental monitoring.

7: How does the independent nitrogen blowing system benefit evaporation?

It ensures smooth, uniform, and efficient sample evaporation by delivering stable nitrogen flow across all positions.

8: What safety and reliability features are included?

This concentrator is equipped with automatic fault detection, temperature deviation calibration, and an alarm function for secure operation.

9: How accurate is the temperature and nitrogen control?

They provide a temperature range from 5°C to 160°C with ±0.5°C accuracy at 40°C, along with adjustable nitrogen flow up to 15 L/min at 0.1 MPa for reproducible results.

10: Are optional blocks available for different sample sizes?

Yes, optional blocks include 10 mm × 12 and 12 mm × 12, allowing flexibility for various laboratory requirements.

11: What is a Sample Concentrator and what is it used for?

A Sample Concentrator is a laboratory device used to evaporate solvents and concentrate multiple samples simultaneously.

12: What is nitrogen blowdown technology in a Sample Concentrator?

Nitrogen blowdown technology involves directing a stream of inert nitrogen gas onto the surface of liquid samples to accelerate solvent evaporation while minimizing oxidation or degradation.

13: How does the compact design benefit laboratory use?

The compact footprint minimizes the use of valuable bench space, making it ideal for crowded or space-limited laboratories without compromising performance.

14: Are these units easy to move or relocate?

Yes, their lightweight and compact design often make them portable and easy to reposition within the lab as needed.

15: Why is concentrating samples important in laboratory workflows?

Concentration improves analyte detectability, ensures more accurate analysis, and allows for better sensitivity in downstream testing methods.

Related Sample Concentrator

Lab Expo Sample Concentrator units are designed for rapid sample evaporation and concentration using controlled heating and nitrogen blowdown methods. The range includes evaporator nitrogen systems with temperature control up to 160℃, multiple block configurations, and timed operation for chemical, pharmaceutical, and analytical sample preparation using a nitrogen gas evaporator setup.