Sample Concentrator LE-SC401

Sample Concentrator LE-SC401

Lab Expo Sample Concentrator LE-SC401 operates with a nitrogen flow rate of 15 L/min, ensuring high precision for efficient and consistent performance. It is equipped with microprocessor-based PID control system for accurate heat regulation. Built in block design for even heat distribution. Our Sample Concentrator is designed for maximum performance with ease of use in demanding lab environments.

$2,242.00 $ 1868

Sample Concentrator LE-SC401 - Specifications

Temperature Control Range 5℃ to 160℃
Block Quantity 1
Needle Length 150mm
Time Range 1min to 99hr 59min
Temperature Accuracy ± 0.5℃ (at 40℃)± 1℃ (at 120℃)
Temperature Uniformity ± 0.5℃
Display Accuracy 0.1℃
Heating Time ≤ 15 min
Maximum Vertical Travel 150 mm
Nitrogen Flow Rate 15 L/min
Nitrogen Pressure 0.1 MPa
Power Consumption 500W
Power Supply AC 220/110V, 50/60 Hz
Dimension 260 × 220 × 475
Weight 7.3 Kg

Sample Concentrator LE-SC401 - Key Features

  • Nitrogen flow rate 15L/min with precise control
  • Microprocessor-based PID control with 0.1C resolution
  • Temperature accuracy ±0.5C at 40°C operating point
  • Maximum vertical travel 150mm for sample positioning

Sample Concentrator LE-SC401 - Applications

FunctionImplementation
Sample evaporation labs15 L/min nitrogen flow enables efficient solvent removal
Quality control testing±0.5℃ temperature accuracy ensures reproducible results
Clinical sample processing1min to 99hr 59min time range supports varied protocols
Research laboratory workflows≤15 min heating time accelerates sample preparation
Industrial QC environments±0.1℃ display accuracy maintains measurement precision

Sample Concentrator LE-SC401 - Optional Accessories

Block- 10.5mm × 50mm

Block- 12.5mm × 50mm

Block- 13.5mm × 50mm

Block- 15.5mm × 50mm

Block- 16.5mm × 16.5mm

Block- 19.5mm × 19.5mm

Block- 20.5mm × 20.5mm

Sample Concentrator LE-SC401 - Catalog

Sample Concentrator LE-SC401 FAQ's

1: What is the main function of the Sample Concentrator LE-SC401?

Our SC401 is designed to evaporate liquid samples using nitrogen blowdown under precise temperature control, ideal for sample prep in research, diagnostics, and quality control labs.

2: What types of laboratories is this concentrator suitable for?

It is widely used in biological research, pharmaceutical development, environmental science, clinical diagnostics, chemical analysis, and food safety testing.

3: Does it include safety features?

Yes, it is equipped with overheat protection, a microprocessor-based PID control system, and aluminium block heating for safe and stable operation.

4: What is the operating time range that can be set?

One can program our device from 1 minute to 99 hours and 59 minutes, making it suitable for both short and long protocols.

5: What optional accessories are available?

We offer a range of precision-engineered blocks and a flow control valve.

6: What type of laboratories benefit most from the SC401?

It is ideal for pharmaceutical, food safety, clinical, and environmental labs requiring precise nitrogen-assisted sample concentration.

7: How quickly does the SC401 reach its operating temperature?

The unit has a heating time of ? 15 minutes, ensuring rapid setup and minimal downtime.

8: Does this concentrator help reduce energy costs?

Yes, with its 500W low-energy heating system, the SC401 offers efficiency while maintaining reliable performance.

9: Can it handle multiple types of sample blocks?

Yes, it supports various optional block sizes, making it versatile for different sample formats.

10: How portable is the SC401 for shared laboratory use?

Our Sample Concentrator weighing just 7.3 kg with a compact footprint, it is easy to move between workstations without compromising stability.

11: What is a Sample Concentrator and what is it used for?

A Sample Concentrator is a laboratory device used to evaporate solvents and concentrate multiple samples simultaneously.

12: What is nitrogen blowdown technology in a Sample Concentrator?

Nitrogen blowdown technology involves directing a stream of inert nitrogen gas onto the surface of liquid samples to accelerate solvent evaporation while minimizing oxidation or degradation.

13: How does the compact design benefit laboratory use?

The compact footprint minimizes the use of valuable bench space, making it ideal for crowded or space-limited laboratories without compromising performance.

14: Are these units easy to move or relocate?

Yes, their lightweight and compact design often make them portable and easy to reposition within the lab as needed.

15: Why is concentrating samples important in laboratory workflows?

Concentration improves analyte detectability, ensures more accurate analysis, and allows for better sensitivity in downstream testing methods.

Related Sample Concentrator

Lab Expo Sample Concentrator units are designed for rapid sample evaporation and concentration using controlled heating and nitrogen blowdown methods. The range includes evaporator nitrogen systems with temperature control up to 160℃, multiple block configurations, and timed operation for chemical, pharmaceutical, and analytical sample preparation using a nitrogen gas evaporator setup.