Request A Quote

Captcha Image

Open Cup Flash Point Tester

Open Cup Flash Point Tester - Open Cup Flash Point Tester  52-OFP100

Open Cup Flash Point Tester 52-OFP100

  • Thermometer : 0 ℃ ~ 360 °C
  • Scale Division : 1 °C
  • Ambient Temperature : ≤ 35 °C
  • Relative Humidity : ≤ 85 %
  • Outer Crucible-Material : Carbon structural steel
  • Outer Crucible-Diameter Of Upper Opening : Φ100 ± 5 mm
  • Outer Crucible-Height : 50 ± 5 mm
  • Outer Crucible-Diameter Of Bottom : Φ56 ± 2 mm
  • Inner Crucible-Material : Carbon structural steel
  • Inner Crucible-Diameter Of Upper Opening : Φ64 ± 1 mm
  • Inner Crucible-Height : 47 ± 1 mm
  • Inner Crucible-Diameter Of Bottom : Φ38± 1 mm
  • Inner Crucible-Scale Line : 12mm away from the rim of upper opening and 18mm away from the rim of upper opening
  • Gas Tube : Φ0.8 ~ Φ1 mm
  • Flame : 3 to 4 mm
  • Heater : Heated by an electric furnace
  • Heating Power : 1000W
  • Dimensions : 410 x 360 x 240 mm
  • Power Consumption : ≤ 1100 W
  • Power Supply : AC 220 V ± 10 %, 50Hz
$670
Open Cup Flash Point Tester - Cleveland Open Cup Flash Point Tester  52-OFP101

Cleveland Open Cup Flash Point Tester 52-OFP101

  • Thermometer : 6 ℃ ~ 400 ℃
  • Scale Division : 2 °C
  • Spout Aperture : 0.6 ~ 0.8 mm
  • Ambient Temperature : 10 ℃ ~ 50 ℃
  • Relative Humidity : ≤ 85 %
  • Dimensions : 480 x 400 x 300 mm
  • Power Consumption : 0 ~ 600 W
  • Power Supply : AC 220 V ± 10 %, 50 Hz
$820
Open Cup Flash Point Tester - Automatic Cleveland Open Cup Flash Point Tester  52-OFP102

Automatic Cleveland Open Cup Flash Point Tester 52-OFP102

  • Ambient Temperature : 10 ℃ ~ 40 °C
  • Relative Humidity : ≤ 80 %
  • Temperature Measurement- Full Scale : Ambient temperature to 300 °C
  • Temperature Measurement- Repeatability : ≤ 8 °C
  • Temperature Measurement- Reproducibility : ≤ 16 °C
  • Temperature Measurement- Resolution : 0.1 °C
  • Test accuracy : 0.002
  • Precision : 0.005
  • Flame : 3 to 4 mm
  • Dimensions : 550 x 470 x 410 mm
  • Power Consumption : ≤ 500 W
  • Power Supply : AC 220 V ± 10 %, 50 Hz
$6640
Open Cup Flash Point Tester - Semi-auto Cleveland Open Cup Flash Point Tester  52-OFP103

Semi-auto Cleveland Open Cup Flash Point Tester 52-OFP103

  • Ambient Temperature : 20 °C ± 5 °C
  • Relative Humidity : ≤ 80 %
  • Temperature Measurement- Full Scale : Ambient temperature to ~ 350 °C
  • Temperature Measurement- Repeatability : Flash point is lower than 150 °C : error is less than 4 °C; Flash point is higher than 150 °C : error is less than 6 °C
  • Temperature Measurement- Resolution : 0.1 °C
  • Dimensions : 690 x 420 x 330 mm
  • Power Consumption : ≤ 400 W
  • Power Supply : AC 220 V ± 10 %, 50 ± 1 Hz
$3980
Open Cup Flash Point Tester - Automatic COC Flash & Fire Point Tester  52-OFP200

Automatic COC Flash & Fire Point Tester 52-OFP200

  • Ambient Temperature : 10 ℃ ~ 40 ℃
  • Relative Humidity : ≤ 85 %
  • Temperature Measurement- Full Scale : Ambient temperature to ~ 400 ℃
  • Temperature Measurement- Repeatability : ≤ 4 ℃
  • Test accuracy : 0.005
  • Reappearance : ≤ 8 times
  • Graduation : 0.1 ℃
  • Dimensions : 620 x 500 x 440 mm
  • Power Consumption : 400 W
  • Power Supply : AC 220 V ± 10 %, 50 Hz
$8470