Lab Expo Semi-prep HPLC 37-SPH100 is equipped with 4 sets of high pressure pumps providing a flow rate variance of 50 ml / min or 100 ml / min and a UV-Vis detector with a wavelength range of 190 to 800 nm. Equipped with a mixing chamber to enhance homogenization and reciprocating pump for consistent flow. With a column size of 10 x 250 mm and particle size of 5 µm or 10 µm, the retention, resolution and selectivity is optimized.
$18,202.00 $ 15168
| Pump Specifications | Model No SPH-A10 SPH-A11 SPH-A12 SPH-A13 Flow rate range 0.001 ~ 50 ml / min 0.001 ~ 50 ml / min 0.001 ~ 100 ml / min 0.001 ~ 100 ml / min Maximum pressure 30 MPa 30 MPa 15 MPa 10 MPa Flow rate accuracy ± 0.35 ± 0.5 ± 0.5 ± 0.5 Flow rate repeatability % ≤ 0.1 ≤ 0.15 ≤ 0.1 ≤ 0.15 Column size 10 x 250 mm 10 x 250 mm 10 x 250 mm 10 x 250 mm Sample loading 35 ~ 60 mg 35 ~ 60 mg 35 ~ 60 mg 35 ~ 60 mg Pressure pulsation 1 % at 10 MPa 1.5 % at 10 MPa 1.5 % at 10 MPa 1.5 % at 10 MPa Flow rate repeatability % ≤ 0.1 ≤ 0.15 Gradient accuracy % ± 2 ± 2 ± 2 ± 2 Gradient repeatability % ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2 Dimension 465 x 315 x 180 mm 455 x 265 x 190 mm 465 x 315 x 180 mm 465 x 315 x 180 mm Power 150 W 150 W 150 W 150 W Power supply 90 V ~ 240 V/ 50 Hz 90 V ~ 240 V/ 60 Hz 90 V ~ 240 V/ 50 Hz 90 V ~ 240 V/ 60 Hz Weight 11.6 kg 11.2 kg 11.6 kg 11.6 kg |
| Detector Specifications | Model No SPH-A20 SPH-A21 SPH-A22 Wavelength range 190 to 800 nm 190 to 800 nm 190 to 800 nm Wavelength accuracy ± 0.5 nm ± 1 nm ± 0.75 nm Wavelength repeatability 0.15 nm 0.3 nm 0.2 nm Band width 8 nm 8 nm 8 nm Optical path Semi flow / analytical Semi flow / analytical Semi flow / analytical Baseline noise ( Static ) Au ≤ ± 0.35 x 10 -5 ≤ ± 0.5 x 10 -5 ≤ ± 0.5 x 10 -5 Baseline drift ( Static ) Au / h ≤ 1 x 10 -4 ≤ 1.5 x 10 -4 ≤ 1.5 x 10 -4 Minimum detection limit ≤ 4 x 10 -8 ≤ 4 x 10 -8 ≤ 4 x 10 -8 Power 150 W 150 W 150 W Power supply 90 V / 50 ~ 60 Hz 90 V / 50 ~ 60 Hz 90 V / 50 ~ 60 Hz Dimension 465 x 315 x 180 mm 465 x 315 x 180 mm 460 x 265 x 190 mm Weight 9.5 kg 9.5 kg 9.2 kg |
| Column Specifications | Inner diameter 100 mm , 20 mm , 30 mm , 50 mm Column length 100 mm , 150 mm , 250 mm , 300 mm Particle size 5 µm , 10 µm |
Function Implementation Quality control labs ± 0.35 flow rate accuracy ensures precise analyte quantification Clinical sample analysis 190 to 800 nm wavelength range enables broad compound detection Research laboratories ≤ 0.1% flow rate repeatability supports reproducible experimental results Industrial testing facilities 35 ~ 60 mg sample loading capacity handles medium-volume preparations Pharmaceutical development ±2% gradient accuracy maintains consistent separation conditions
| Accessory | Quantity |
| Autosampler | 1 |
| Fraction collector ( 144 tubes , 12 mm test tubes ) | 1 |
| Fraction valve ( 6 channel ) | 1 |