0

HPLC

Lab Expo offers a comprehensive range of HPLC, including analytical, preparative, standard, semi-preparative, and more. They are designed for precise separation, identification, and quantification of compounds with exceptional accuracy. They have digital displays, corrosion-resistant parts, and microprocessor controls. These come equipped with automatic sample injection, high-resolution detectors, and real-time data monitoring. These safety features include overpressure protection, leak detection, and system alarms. Our HPLC models ensure reproducible results with minimal maintenance.

HPLC System 37-HPS100

  • High pressure pump : Single pump
  • Flow rate range : 0.001 to 9.999 mL / min (0.001 mL / min increment)
  • Pressure range : ≤ 0.5 MPa (0 to 42 MPa)
  • Flow rate precision : RSD < 0.06 %
$10300

HPLC System 37-HPS101

  • High pressure pump : Two sets of pump
  • Flow rate range : 0.001 to 9.999 mL / min (0.001 mL / min increments)
  • Pressure range : ≤ 0.5 MPa (0 to 42 MPa)
  • Flow rate precision : RSD < 0.06 %
$15010

HPLC System 37-HPS102

  • High pressure pump : High pressure gradient pump
  • Peak operating pressure : 45 MPa, Stainless steel pump
  • Pressure : ± 0.02 MPa
  • Flow rate range : 0.001 to 9.999 mL / min
$11330

HPLC System 37-HPS103

  • High pressure pump : High pressure constant-current infusion pump
  • Infusion Way : Micro volume series dual-piston
  • Infusion pressure : 0 to 9999 Psi
  • Flow rate : ≤ 0.5 %
$8110

Preparative HPLC 37-PHP100

  • Dimension : 750 x 860 x 1280 mm ( 100 ml , 250 ml , 500 ml , 1000 ml ) , 810 x 950 x 1310 mm ( 3 L )
  • Wetted material : 316 L and PTFE
  • Power : < 1500 W
  • Mobility : With castor
$27425

Semi-prep HPLC 37-SPH100

  • Pump Specifications :
    Model No SPH-A10 SPH-A11 SPH-A12 SPH-A13
    Flow rate range 0.001 ~ 50 ml / min 0.001 ~ 50 ml / min 0.001 ~ 100 ml / min 0.001 ~ 100 ml / min
    Maximum pressure 30 MPa 30 MPa 15 MPa 10 MPa
    Flow rate accuracy ± 0.35 ± 0.5 ± 0.5 ± 0.5
    Flow rate repeatability % ≤ 0.1 ≤ 0.15 ≤ 0.1 ≤ 0.15
    Column size 10 x 250 mm 10 x 250 mm 10 x 250 mm 10 x 250 mm
    Sample loading 35 ~ 60 mg 35 ~ 60 mg 35 ~ 60 mg 35 ~ 60 mg
    Pressure pulsation 1 % at 10 MPa 1.5 % at 10 MPa 1.5 % at 10 MPa 1.5 % at 10 MPa
    Flow rate repeatability % ≤ 0.1 ≤ 0.15
    Gradient accuracy % ± 2 ± 2 ± 2 ± 2
    Gradient repeatability % ≤ 0.2 ≤ 0.2 ≤ 0.2 ≤ 0.2
    Dimension 465 x 315 x 180 mm 455 x 265 x 190 mm 465 x 315 x 180 mm 465 x 315 x 180 mm
    Power 150 W 150 W 150 W 150 W
    Power supply 90 V ~ 240 V/ 50 Hz 90 V ~ 240 V/ 60 Hz 90 V ~ 240 V/ 50 Hz 90 V ~ 240 V/ 60 Hz
    Weight 11.6 kg 11.2 kg 11.6 kg 11.6 kg
  • Detector Specifications :
    Model No SPH-A20 SPH-A21 SPH-A22
    Wavelength range 190 to 800 nm 190 to 800 nm 190 to 800 nm
    Wavelength accuracy ± 0.5 nm ± 1 nm ± 0.75 nm
    Wavelength repeatability 0.15 nm 0.3 nm 0.2 nm
    Band width 8 nm 8 nm 8 nm
    Optical path Semi flow / analytical Semi flow / analytical Semi flow / analytical
    Baseline noise ( Static ) Au ≤ ± 0.35 x 10 -5 ≤ ± 0.5 x 10 -5 ≤ ± 0.5 x 10 -5
    Baseline drift ( Static ) Au / h ≤ 1 x 10 -4 ≤ 1.5 x 10 -4 ≤ 1.5 x 10 -4
    Minimum detection limit ≤ 4 x 10 -8 ≤ 4 x 10 -8 ≤ 4 x 10 -8
    Power 150 W 150 W 150 W
    Power supply 90 V / 50 ~ 60 Hz 90 V / 50 ~ 60 Hz 90 V / 50 ~ 60 Hz
    Dimension 465 x 315 x 180 mm 465 x 315 x 180 mm 460 x 265 x 190 mm
    Weight 9.5 kg 9.5 kg 9.2 kg
  • Column Specifications :
    Inner diameter 100 mm , 20 mm , 30 mm , 50 mm
    Column length 100 mm , 150 mm , 250 mm , 300 mm
    Particle size 5 µm , 10 µm
$12640