Lab Expo HPLC System LE-HCL103 operates at a peak pressure of 45 MPa, ensuring to ensure stable performance. It features an adjustable sample volume from 0 to 1 mL to allow flexible control. Incorporated with patented gradient mixer for precise solvent blending. Equipped with anti-control software for operational control and enhanced safety. Our HPLC system delivers high efficiency and user-friendly operation, advancing modern chromatographic technology.
$20,146.00 $ 16788
| Peak Operating Pressure | 45 MPa |
| Flow Rate Range | 0.001 to 9.999 mL/min |
| Flow Rate Repeatability | RSD ≤ 0.1% |
| Flow Rate Precision | ±5% |
| Gradient Error | ≤0.5% |
| Qualitative Analysis | RSD ≤ 0.2% |
| Quantitative Repeatability | RSD ≤ 0.2% |
| UV Detector Wavelength Range | 190 to 680 nm |
| Wavelength Error | ≤ ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Limit of Detection | ≤ 2 × 10⁻⁹ g/mL (Naphthalene in Methanol) |
| Baseline Noise | ≤ 2 × 10⁻⁵ AU (Methanol, 1 mL/min, 254 nm, 20 ºC) |
| Drift | ≤ 5 × 10⁻⁴ AU/h (Methanol, 1 mL/min, 254 nm, 20 ºC) |
| Flow Cell Volume | 8 μL |
| Column Oven Temp. Range | Room Temp. +5 ºC to 80 ºC |
| Constant Temp. Accuracy | ±1 ºC |
| Constant Temp. Precision | ≤ 0.1 ºC |
| Temp. Setting Resolution | 0.1 ºC |
| Automatic Injector Capacity | Max. 2 mL, 6 × 25 = 150 units |
| Sample Volume | 0 to 1 mL, Adjustable |
| Sample Residual (Injector) | < 0.02% |
| Sample Residual (System) | ≤ 0.01% |
| Pressure Error | ±0.02 MPa |
| Power Supply | 220 V ±10%, 50 Hz, 250 W |
| Dimensions | 520 × 420 × 160 mm |
Function Implementation Quality control labs ±1 ºC constant temp. accuracy supports repeatable analytical results Clinical diagnostics ≤ 2 × 10⁻⁹ g/mL detection limit enables trace analyte identification Research laboratories 0.001 to 9.999 mL/min flow rate range accommodates diverse separation methods Industrial testing Peak operating pressure of 45 MPa ensures stable performance under high load Pharmaceutical analysis RSD ≤ 0.2% qualitative analysis precision supports method validation protocols
Lab Expo Standard HPLC systems are configured for high pressure chromatography and routine analytical separation workflows in pharmaceutical, chemical, and research laboratories. These liquid chromatography equipment models support flow rates from 0.001 to 9.999 mL/min with operating pressures up to 45 MPa and flow repeatability of RSD ≤ 0.1%. Systems integrate single or dual pump assemblies, double-piston solvent delivery, and analytical pump head configurations for controlled compound separation and quantitative analysis.