Chromatography

Lab Expo offers a variety of chromatography systems, including ion chromatography, gas chromatography, and gas chromatography mass spectrometry. They provide superior temperature control with several phases and accurate flow rate management. They have user-friendly interfaces, detectors, and built-in eluent generators. These systems incorporate electronic flow control, automated suppressors, and low-pressure degassing technology. They enable simultaneous study of various components, which boosts productivity. Our chromatography systems are engineered for dependability, stability, and efficiency in complex sample analysis.

Gas Chromatography 30-GCG100

  • Chromatography column type : Capillary and Packed column
  • Chromatography column length : 100 to 500 mm
  • Chromatography column diameter : 0.2 to 0.5 mm
  • Temperature operating range : Higher than the room temperature of 5 ℃ to 450 ℃
$4884

Gas Chromatography 30-GCG101

  • Chromatography column type : Capillary or Packed column
  • Chromatography column length : 100 to 300 mm
  • Chromatography column diameter : 0.2 to 0.5 mm
  • Temperature operating range : Higher than the room temperature of 5 °C to 450°C
    Liquid nitrogen cold trap: -80 °C to 400 °C
    Dry ice cold trap: -55 °C to 400 °C
$17112

Gas-Chromatograph-Mass Spectrometer 30-GMS100

  • Gas Chromatography Specifications :
    Specification Details
    Model No GC-87
    Flow rate 1 ~ 1.5 ml / min
    Maximum flow rate 10 ml / min
    Inlet temperature 450 °C
    Pressure range 0 ~ 100 psi
    Heating rate Up to 120 °C / min
    Room temperature 4 °C ~ 450 °C
    Pressure control mode Electronic pressure control (Supports CV and CC)
    Split mode Split / split less
    Split ratio 1000 : 1
    Temperature programming 7 stages / 8 platforms
    Auto sampler Optional
  • Mass Spectrometry Specifications :
    Specification Details
    Model No MS-89
    Mass range 1.5 ~ 1000 amu
    Ion – source temperature 100 °C ~ 350 °C
    GC-MS interface temperature 450 °C
    Scan rate Up to 10000 amu/s
    Stability ± 0.10 amu / 48 hrs.
    Filament emission current 0 ~ 350 µA
    EI source ionization energy 5 eV ~ 250 eV
    Resolution Unit resolution
    Detector High energy dynode electron multiplier
    Sensitivity Full scan (S / N is ≥ 30 : 1)
    Vacuum Turbo molecular pump (67 L/s)
$55200
Ion chromatograph system 30-ICG200
  • Ion Chromatographic Pump :
    Specification Details
    Type High pressure and low pulse double plunger tandem advection pump
    Maximum pressure 35 MPa (PEEK)
    Pressure display accuracy ≤ 0.1 MPa
    Flow stability (0.2 to 0.5) ml/ min ≤ 3%
    (0.5 to 1.0) ml/ min ≤ 2%
    > 1.0 ml/ min 2%
    Flow range 0.001 to 9.999 ml/ min
    Pressure pulse ≤ 0.5%
  • Conductivity detector :
    Specification Details
    Type Temperature Control and Bipolar Conductivity Detector
    Detection mode Bipolar conductivity detection
    Cell volume ≤ 0.8 µL
    Detection range 0 to 35000 µS/cm
    Detection resolution ≤ 0.0020 nS/cm
    Output voltage - 6000 to +6000 mV (adjustable)
    Baseline noise ≤ 0.05 % F.S.
    Baseline drift ≤ 3 % FS/30 min
    Operating temperature range Room temperature +5 to 60°C (41 to 140°F)
    Controlling temperature accuracy ± 0.01°C
    Maximum pressure 10 MPa
    Linear range ≥ 103
    Instruments linearity ≥ 0.999
    Quantitative repeatability ≤ 1.0 %
    Qualitative repeatability ≤ 1.0 %
    Minimum detectable concentration Cl ≤ 0.0005 µg/ml
    BrO3 ≤ 0.001 µg/ml
    Li+ ≤ 0.001 µg/ml
  • Flow system :
    Specification Details
    Plastic flow path Made of PEEK materials
    Six way Valve PEEK material, 5000 psi pressure, independent automatic collection and flow function
  • Degassing Device :
    Specification Details
    Inner volume 300 µl
    Degassing volume 7.5 ml
    Maximum flow rate 10 ml/min
    Degassing efficiency Degassing 90% at 1 ml/min
    Organic tolerance 1
$45048
Ion chromatograph system 30-ICG201
  • Ion Chromatographic Pump :
    Specification Details
    Type High pressure and low pulse double plunger tandem advection pump
    Maximum pressure 35 MPa (PEEK)
    Pressure display accuracy ≤ 0.1 MPa
    Flow stability (0.2 to 0.5) ml/min ≤ 3%
    (0.5 to 1.0) ml/min ≤ 2%
    > 1.0 ml/min 2%
    Flow range 0.001 to 9.999 ml/min
    Pressure pulse ≤ 0.5%
  • Conductivity detector :
    Specification Details
    Type Temperature Control and Bipolar Conductivity Detector
    Detection mode Bipolar conductivity detection
    Cell volume ≤ 0.8 µL
    Detection range 0 to 45000 µS/cm
    Detection resolution ≤ 0.0020 nS/cm
    Output voltage - 6000 to +6000 mV (adjustable)
    Baseline noise ≤ 0.05 % F.S.
    Baseline drift ≤ 3 % FS/30 min
    Operating temperature range Room temperature +5 to 60°C (41 to 140°F)
    Controlling temperature accuracy ± 0.01°C
    Maximum pressure 10 MPa
    Linear range ≥ 103
    Instruments linearity ≥ 0.999
    Quantitative repeatability ≤ 1.0 %
    Qualitative repeatability ≤ 1.0 %
    Minimum detectable concentration Cl ≤ 0.0005 µg/ml
    BrO3 ≤ 0.001 µg/ml
    Li+ ≤ 0.001 µg/ml
  • Flow system :
    Specification Details
    Plastic flow path Made of PEEK materials
    Six-way Valve PEEK material, 5000 psi pressure, independent automatic collection and flow function
  • Power supply : 150 W
$52440

Gas Chromatograph 65-GC100

  • Environment Temperature : 5-35°C
  • Relative Humidity : ≤85%
  • Working Environment : The room must be free from corrosive gas and hydrogen gas cylinder must be kept away from the fire. There must be no turbulent shock and strong magnetic field, which will affect the operation.
  • Power Supply : 200V ± (5% - 10%)

Gas Chromatograph 65-GC101

  • Operation : 192 × 64 periodic lattice liquid crystal
  • Temperature Control : 5℃ to 420℃ at room temperature (protection temperature 200℃)
  • Temperature Increment : 1℃
  • Temperature Control Accuracy : <± 0.1℃ (measured at 200℃)
$18504

Gas Chromatograph 65-GC102

  • Environment Temperature : 5-35°C
  • Relative Humidity : ≤85%
  • Working Environment : The room must be free from corrosive gas and hydrogen gas cylinder must be kept away from the fire. There must be no turbulent shock and strong magnetic field, which will affect the operation.
  • Power Supply : 200V ± (5% - 10%)
Gas Chromatograph 65-GC103
  • Environment Temperature : 5-35°C
  • Relative Humidity : ≤85%
  • Working Environment : The room must be free from corrosive gas and hydrogen gas cylinder must be kept away from the fire. There must be no turbulent shock and strong magnetic field, which will affect the operation.
  • Power Supply : 200V ± (5% - 10%)

Gas Chromatograph 65-GC104

  • Temperature Range : RT to 450 °C
  • Temperature Accuracy : ≤ ± 0.1℃
  • Temperature Program : 16-phase
  • Maximum Temperature Heating Rate : 40℃/min
$6732