Gas Chromatograph 65-GC101

Gas Chromatograph 65-GC101

Gas Chromatograph 65-GC101 performance is enhanced by 8 orders temperature programming with precise temperature control across multiple areas. It includes column boxes, TCD, FID, and conversion furnaces. It has a temperature range of 5℃ to 420℃ at room temperature and accuracy better than ± 0.1 ℃. Our Chromatograph possess accurate pressure and flow measurements using pointer-type or electronic instruments.

$22,205.00 $ 18504

Gas Chromatograph 65-GC101 - Specifications

Operation 192 × 64 periodic lattice liquid crystal
Temperature Control 5℃ to 420℃ at room temperature (protection temperature 200℃)
Temperature Increment 1℃
Temperature Control Accuracy
Temperature Control Area 6 Ways
Temperature-Programmed Order 8 Order
Programming Rate 0.1 to 39℃/min (common type); 0.1 to 80℃/min (high speed)
Gas Control Optional pressure flow control mode of the mechanical valve control mode, electronic
Gas Pressure Flow Measurement Pointer type pressure meter or electronic pressure, flow pattern
Measuring Way 16 Ways, Single module
Measuring Range 0 to 0.3MPa (pressure); 0 to 500sccm (flow)
Measuring Resolution 0.01kPa (pressure); 0.01sccm (flow)
Working Mode EPC, EFC, Constant current mode, Constant voltage mode
Working Gas Nitrogen, Air, Hydrogen, Helium, Argon
Detector Type TCD and FID
TCD Sensitivity S ≥ 2500mV•ml/mg (sixteen alkyl) (1, 2, 4, 8 times enlarged, optional)
TCD Baseline Noise ≤ 20μV
TCD Baseline Drift ≤ 30 μV/30min
TCD Linear Range ≥10⁴
FID Detection Limit ≤ 1×10⁻¹¹g/s (sixteen alkyl)
FID Baseline Noise ≤5×10⁻¹⁴A
FID Baseline Drift ≤1×10⁻¹³A/30min
FID Linear Range ≥10⁶
Dimensions 52 × 48 × 55 cm
Net Weight 53 Kg

Gas Chromatograph 65-GC101 - Key Features

  • Temperature control 5 C to 420 C with accuracy better than plus or minus 0.1 C
  • 8-order temperature programming with up to 6 control zones
  • Gas pressure range 0 to 0.3 MPa with 0.01 kPa resolution
  • Flow measurement 0 to 500 sccm with 0.01 sccm resolution
  • TCD and FID detectors with linear range up to 10⁴ and 10⁶

Gas Chromatograph 65-GC101 - Applications

FunctionImplementation
Multi-component separation8-order temperature programming manages complex mixtures
Trace compound detectionFID limit ≤1×10⁻¹¹ g/s enables low-level analysis
Gas composition analysisTCD sensitivity supports quantification of permanent gases
Pharmaceutical testingPrecise temperature and flow control ensure reproducible results
Environmental sample evaluationStable baseline drift and noise maintain measurement accuracy

Gas Chromatograph 65-GC101 - Standard Accessories

  • Power wire
  • Grounding Wire
  • 1 Set of Connections Pipes and accessories
  • 2 Fuse
  • 1 Set of Hydrogen Generator
  • 1 Set of Air Generator

Gas Chromatograph 65-GC101 - Optional Accessories

  • Computer 1080 USD

  • 27 samples of Headspace autosampler 18880 USD

  • Printer 840 USD

Gas Chromatograph 65-GC101 - Catalog

Related Gas Chromatography

Lab Expo gas chromatography systems include excellent temperature management, offering numerous stages and a broad temperature range. They come with a variety of detectors that provide great sensitivity and stability. These devices have LCD screens and several injector choices. They provide dependability through self-diagnosis, data storage during power outages, and improved insulation. Our gas chromatography systems examine gas, solid, and liquid samples and return exact findings.