Multi-parameter water quality Analyzer

Multi parameter water quality analyzer 25-MWA100
COD COD determination range : 2 to 10000 mg/ L
COD measurement accuracy : COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit : 0.1 mg/ L
COD measurement time : 20 minutes
COD repeatability : ≤ ± 5 %
Processing sample number per batch :
Consumables for colorimetric COD measurement : Colorimetric tubes and Cuvette
COD reactor digestion temperature : 165 ± 0.5°C
COD reactor digestion time : 10 min
COD reactor time setting switches : 3 pcs
Anti-chlorine interference : (Cl) < 1000 mg/ L No effect
Ammonia nitrogen Ammonia nitrogen determination range : 0.02 to 60 mg/ L
Ammonia nitrogen measurement accuracy : ≤ ± 10 %
Ammonia nitrogen minimum detection limit : 0.01 mg/ L
Ammonia nitrogen measurement time : 10 to 15 minutes
Ammonia nitrogen repeatability : ≤ ± 5 %
Processing sample number per batch :
Consumables for colorimetric ammonia nitrogen measurement : Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches : 3 pcs
Total phosphorous Total phosphorous determination range : 0.002 to 20 mg/ L
Total phosphorous total phosphorous measurement accuracy : ≤ ± 5 %
Total phosphorous minimum detection limit : 0.001 mg/ L
Total phosphorous measurement time : 35 to 50 minutes
Total phosphorous repeatability : ≤ ± 5 %
Processing sample number per batch :
Consumables for colorimetric total phosphorous measurement : Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature : 120 ± 0.5°C
Total phosphorous reactor digestion time : 30 min
Total phosphorous reactor time setting switches : 3 pcs
Turbidity Turbidity determination range : 0.5 to 400 NTU
Turbidity measurement accuracy : ≤ ± 5 %
Turbidity minimum detection limit : 0.1 NTU
Turbidity measurement time : 1 minute
Turbidity repeatability : ≤ ± 5 %
Consumables for colorimetric turbidity measurement : Colorimetric Cuvette
Multi parameter water quality analyzer 25-MWA101
COD COD determination range : 5 to 5000 mg/ L
COD measurement accuracy : COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit : 0.1 mg/ L
COD measurement time : 20 minutes
COD repeatability : ≤ ± 5 %
Processing sample number per batch : 12 pcs
Consumables for colorimetric COD measurement : Colorimetric tubes and Cuvette
COD reactor digestion temperature : 165 ± 0.5°C
COD reactor digestion time : 10 min
COD reactor time setting switches : 3 pcs
Anti-chlorine interference : (Cl) < 1000 mg/ L No effect
Ammonia nitrogen Ammonia nitrogen determination range : 0.02 to 30 mg/ L
Ammonia nitrogen measurement accuracy : ≤ ± 10 %
Ammonia nitrogen minimum detection limit : 0.01 mg/ L
Ammonia nitrogen measurement time : 10 to 15 minutes
Ammonia nitrogen repeatability : ≤ ± 5 %
Processing sample number per batch : 20 pcs
Consumables for colorimetric ammonia nitrogen measurement : Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches : 3 pcs
Total phosphorous Total phosphorous determination range : 0.002 to 10 mg/ L
Total phosphorous total phosphorous measurement accuracy : ≤ ± 5 %
Total phosphorous minimum detection limit : 0.001 mg/ L
Total phosphorous measurement time : 35 to 50 minutes
Total phosphorous repeatability : ≤ ± 5 %
Processing sample number per batch : 12 pcs
Consumables for colorimetric total phosphorous measurement : Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature : 120 ± 0.5°C
Total phosphorous reactor digestion time : 30 min
Total phosphorous reactor time setting switches : 3 pcs
Turbidity Turbidity determination range : 0.5 to 400 NTU
Turbidity measurement accuracy : ≤ ± 5 %
Turbidity minimum detection limit : 0.1 NTU
Turbidity measurement time : 1 minute
Turbidity repeatability : ≤ ± 5 %
Consumables for colorimetric turbidity measurement : Colorimetric Cuvette